There is an incorrect conversion between numeric types vulnerability in NI grpc-device due to missing range checks in CodeGen.  This may silently discard high bits if a size value exceeded the target type's range. This affects NI grpc-device 2.17.0 and prior versions.
History

Fri, 19 Jun 2026 18:15:00 +0000

Type Values Removed Values Added
Description There is an incorrect conversion between numeric types vulnerability in NI grpc-device due to missing range checks in CodeGen.  This may silently discard high bits if a size value exceeded the target type's range. This affects NI grpc-device 2.17.0 and prior versions.
Title Incorrect Conversion between Numeric Types in NI grpc-device due to missing range checks in CodeGen
First Time appeared Ni
Ni grpc-device
Ni instrumentstudio
Weaknesses CWE-681
CPEs cpe:2.3:a:ni:grpc-device:*:*:*:*:*:*:*:*
cpe:2.3:a:ni:instrumentstudio:*:*:*:*:*:*:*:*
Vendors & Products Ni
Ni grpc-device
Ni instrumentstudio
References
Metrics cvssV3_1

{'score': 3.7, 'vector': 'CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N'}

cvssV4_0

{'score': 6.3, 'vector': 'CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N'}