A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'RestoreFromBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25923)
History

Wed, 16 Apr 2025 19:15:00 +0000

Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}


Wed, 16 Apr 2025 17:45:00 +0000

Type Values Removed Values Added
Description A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'RestoreFromBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25923)
Weaknesses CWE-89
References
Metrics cvssV3_1

{'score': 8.8, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H'}

cvssV4_0

{'score': 8.7, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N'}


cve-icon MITRE

Status: PUBLISHED

Assigner: siemens

Published:

Updated: 2025-04-16T18:04:16.027Z

Reserved: 2025-03-12T13:34:52.658Z

Link: CVE-2025-29905

cve-icon Vulnrichment

Updated: 2025-04-16T18:04:12.365Z

cve-icon NVD

Status : Awaiting Analysis

Published: 2025-04-16T18:16:04.817

Modified: 2025-04-17T20:22:16.240

Link: CVE-2025-29905

cve-icon Redhat

No data.