Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:ofono_project:ofono:1.34:*:*:*:*:*:*:*", "matchCriteriaId": "61E9AB52-5F6C-43E6-AF07-343081C774A5", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "cveTags": [], "descriptions": [{"lang": "en", "value": "oFono CUSD Stack-based Buffer Overflow Code Execution Vulnerability. This vulnerability allows local attackers to execute arbitrary code on affected installations of oFono. An attacker must first obtain the ability to execute code on the target modem in order to exploit this vulnerability.\n\nThe specific flaw exists within the parsing of responses from AT+CUSD commands. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-23195."}, {"lang": "es", "value": "Vulnerabilidad de ejecuci\u00f3n de c\u00f3digo de desbordamiento de b\u00fafer basado en pila de oFono CUSD. Esta vulnerabilidad permite a atacantes locales ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de oFono. Un atacante primero debe obtener la capacidad de ejecutar c\u00f3digo en el m\u00f3dem de destino para poder aprovechar esta vulnerabilidad. La falla espec\u00edfica existe en el an\u00e1lisis de las respuestas de los comandos AT+CUSD. El problema se debe a la falta de una validaci\u00f3n adecuada de la longitud de los datos proporcionados por el usuario antes de copiarlos en un b\u00fafer basado en pila. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto de la ra\u00edz. Era ZDI-CAN-23195."}], "id": "CVE-2024-7539", "lastModified": "2024-08-29T17:59:05.223", "metrics": {"cvssMetricV30": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "zdi-disclosures@trendmicro.com", "type": "Secondary"}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2024-08-06T00:15:35.053", "references": [{"source": "zdi-disclosures@trendmicro.com", "tags": ["Third Party Advisory"], "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1079/"}], "sourceIdentifier": "zdi-disclosures@trendmicro.com", "vulnStatus": "Analyzed", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-787"}], "source": "nvd@nist.gov", "type": "Primary"}, {"description": [{"lang": "en", "value": "CWE-121"}], "source": "zdi-disclosures@trendmicro.com", "type": "Secondary"}]}