This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the handling of OCPP messages. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root.
Metrics
Affected Vendors & Products
References
Link | Providers |
---|---|
https://www.zerodayinitiative.com/advisories/ZDI-24-1053/ |
![]() ![]() |
History
Fri, 31 Jan 2025 19:15:00 +0000
Type | Values Removed | Values Added |
---|---|---|
Weaknesses | CWE-77 | |
Metrics |
cvssV3_1
|
Fri, 31 Jan 2025 00:00:00 +0000
Type | Values Removed | Values Added |
---|---|---|
Description | This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OCPP messages. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. | |
Title | ChargePoint Home Flex OCPP bswitch Command Injection | |
References |
|

Status: PUBLISHED
Assigner: icscert
Published:
Updated: 2025-01-31T19:04:07.235Z
Reserved: 2024-01-25T00:14:42.599Z
Link: CVE-2024-23971

Updated: 2025-01-31T19:03:44.337Z

Status : Received
Published: 2025-01-31T00:15:09.920
Modified: 2025-01-31T19:15:18.030
Link: CVE-2024-23971