Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
History

Thu, 16 Jan 2025 22:15:00 +0000

Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'yes', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}


cve-icon MITRE

Status: PUBLISHED

Assigner: icscert

Published:

Updated: 2025-01-16T22:02:07.832Z

Reserved: 2022-09-29T14:08:03.175Z

Link: CVE-2022-41778

cve-icon Vulnrichment

Updated: 2024-08-03T12:49:44.036Z

cve-icon NVD

Status : Modified

Published: 2023-01-13T00:15:09.480

Modified: 2024-11-21T07:23:49.630

Link: CVE-2022-41778

cve-icon Redhat

No data.