Azure RTOS USBX is a USB host, device, and on-the-go (OTG) embedded stack. In versions prior to 6.1.10, an attacker can cause a buffer overflow by providing the Azure RTOS USBX host stack a HUB descriptor with `bNbPorts` set to a value greater than `UX_MAX_TT` which defaults to 8. For a `bNbPorts` value of 255, the implementation of `ux_host_class_hub_descriptor_get` function will modify the contents of `hub` -> `ux_host_class_hub_device` -> `ux_device_hub_tt` array violating the end boundary by 255 - `UX_MAX_TT` items. The USB host stack needs to validate the number of ports reported by the hub, and if the value is larger than UX_MAX_TT, USB stack needs to reject the request. This fix has been included in USBX release 6.1.10.
Metrics
Affected Vendors & Products
References
History
No history.

Status: PUBLISHED
Assigner: GitHub_M
Published:
Updated: 2024-08-03T06:17:54.276Z
Reserved: 2022-04-13T00:00:00
Link: CVE-2022-29223

No data.

Status : Modified
Published: 2022-05-24T15:15:07.977
Modified: 2024-11-21T06:58:45.240
Link: CVE-2022-29223

No data.