The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
Metrics
Affected Vendors & Products
References
Link | Providers |
---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03 |
![]() ![]() |
History
Wed, 16 Apr 2025 16:15:00 +0000
Type | Values Removed | Values Added |
---|---|---|
Metrics |
ssvc
|

Status: PUBLISHED
Assigner: icscert
Published:
Updated: 2025-04-16T16:10:43.133Z
Reserved: 2022-04-14T00:00:00.000Z
Link: CVE-2022-1368

Updated: 2024-08-03T00:03:05.837Z

Status : Modified
Published: 2022-09-06T23:15:08.240
Modified: 2024-11-21T06:40:35.250
Link: CVE-2022-1368

No data.