The Eclipse Hono AMQP and MQTT protocol adapters do not check whether an authenticated gateway device is authorized to receive command & control messages when it has subscribed only to commands for a specific device. The missing check involves verifying that the command target device is configured giving permission for the gateway device to act on its behalf. This means an authenticated device of a certain tenant, notably also a non-gateway device acting like a gateway, may receive command & control messages targeted at a different device of the same tenant without corresponding permissions getting checked.
Metrics
Affected Vendors & Products
References
Link | Providers |
---|---|
https://bugs.eclipse.org/bugs/show_bug.cgi?id=569856 |
![]() ![]() |
History
No history.

Status: PUBLISHED
Assigner: eclipse
Published:
Updated: 2024-08-04T16:11:36.045Z
Reserved: 2020-10-19T00:00:00
Link: CVE-2020-27220

No data.

Status : Modified
Published: 2021-01-14T23:15:13.040
Modified: 2024-11-21T05:20:53.370
Link: CVE-2020-27220

No data.