Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.
Metrics
Affected Vendors & Products
References
History
No history.

Status: PUBLISHED
Assigner: icscert
Published:
Updated: 2024-09-16T21:07:54.228Z
Reserved: 2017-02-16T00:00:00
Link: CVE-2017-6015

No data.

Status : Modified
Published: 2018-05-11T13:29:00.297
Modified: 2024-11-21T03:28:54.360
Link: CVE-2017-6015

No data.