Total
29469 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2022-43486 | 1 Buffalo | 26 Wcr-1166ds, Wcr-1166ds Firmware, Wex-1800ax4 and 23 more | 2025-04-17 | 6.8 Medium |
Hidden functionality vulnerability in Buffalo network devices allows a network-adjacent attacker with an administrative privilege to enable the debug functionalities and execute an arbitrary command on the affected devices. | ||||
CVE-2025-2921 | 1 Netis-systems | 2 Netis Wf-2404, Netis Wf-2404 Firmware | 2025-04-17 | 6.4 Medium |
A vulnerability classified as critical has been found in Netis WF-2404 1.1.124EN. Affected is an unknown function of the file /etc/passwd. The manipulation with the input Realtek leads to use of default password. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2025-2919 | 1 Netis-systems | 2 Netis Wf-2404, Netis Wf-2404 Firmware | 2025-04-17 | 6.8 Medium |
A vulnerability was found in Netis WF-2404 1.1.124EN. It has been declared as critical. This vulnerability affects unknown code of the component UART. The manipulation leads to hardware allows activation of test or debug logic at runtime. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2022-42454 | 1 Hcltechsw | 1 Bigfix Insights For Vulnerability Remediation | 2025-04-16 | 6.4 Medium |
Insights for Vulnerability Remediation (IVR) is vulnerable to man-in-the-middle attacks that may lead to information disclosure. This requires privileged network access. | ||||
CVE-2022-25940 | 1 Lite-server Project | 1 Lite-server | 2025-04-16 | 7.5 High |
All versions of package lite-server are vulnerable to Denial of Service (DoS) when an attacker sends an HTTP request and includes control characters that the decodeURI() function is unable to parse. | ||||
CVE-2022-43543 | 3 Docomo, Kddi, Softbank | 3 \+ Message, \+ Message, \+ Message | 2025-04-16 | 5.4 Medium |
KDDI +Message App, NTT DOCOMO +Message App, and SoftBank +Message App contain a vulnerability caused by improper handling of Unicode control characters. +Message App displays text unprocessed, even when control characters are contained, and the text is shown based on Unicode control character's specifications. Therefore, a crafted text may display misleading web links. As a result, a spoofed URL may be displayed and phishing attacks may be conducted. Affected products and versions are as follows: KDDI +Message App for Android prior to version 3.9.2 and +Message App for iOS prior to version 3.9.4, NTT DOCOMO +Message App for Android prior to version 54.49.0500 and +Message App for iOS prior to version 3.9.4, and SoftBank +Message App for Android prior to version 12.9.5 and +Message App for iOS prior to version 3.9.4 | ||||
CVE-2020-10632 | 1 Emerson | 1 Openenterprise Scada Server | 2025-04-16 | 8.8 High |
Inadequate folder security permissions in Emerson OpenEnterprise versions through 3.3.4 may allow modification of important configuration files, which could cause the system to fail or behave in an unpredictable manner. | ||||
CVE-2022-22985 | 1 Ipcomm | 2 Ipdio, Ipdio Firmware | 2025-04-16 | 8.8 High |
The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the specific web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to review history. | ||||
CVE-2022-24915 | 1 Ipcomm | 2 Ipdio, Ipdio Firmware | 2025-04-16 | 8 High |
The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to upload, copy, download, or delete an existing configuration (Administrative Services). | ||||
CVE-2021-43939 | 1 Smartptt | 1 Smartptt Scada | 2025-04-16 | 8.8 High |
Elcomplus SmartPTT is vulnerable when a low-authenticated user can access higher level administration authorization by issuing requests directly to the desired endpoints. | ||||
CVE-2022-2661 | 1 Sequi | 2 Portbloque S, Portbloque S Firmware | 2025-04-16 | 9.9 Critical |
Sequi PortBloque S has an improper authorization vulnerability, which may allow a low-privileged user to perform administrative functions using specifically crafted requests. | ||||
CVE-2021-23173 | 1 Philips | 1 Engage | 2025-04-16 | 2.6 Low |
The affected product is vulnerable to an improper access control, which may allow an authenticated user to gain unauthorized access to sensitive data. | ||||
CVE-2022-21196 | 1 Airspan | 9 A5x, A5x Firmware, C5c and 6 more | 2025-04-16 | 10 Critical |
MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 does not perform proper authorization and authentication checks on multiple API routes. An attacker may gain access to these API routes and achieve remote code execution, create a denial-of-service condition, and obtain sensitive information. | ||||
CVE-2021-27426 | 1 Ge | 38 Multilin B30, Multilin B30 Firmware, Multilin B90 and 35 more | 2025-04-16 | 9.8 Critical |
GE UR IED firmware versions prior to version 8.1x with “Basic” security variant does not allow the disabling of the “Factory Mode,” which is used for servicing the IED by a “Factory” user. | ||||
CVE-2021-27474 | 1 Rockwellautomation | 1 Factorytalk Assetcentre | 2025-04-16 | 10 Critical |
Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier does not properly restrict all functions relating to IIS remoting services. This vulnerability may allow a remote, unauthenticated attacker to modify sensitive data in FactoryTalk AssetCentre. | ||||
CVE-2021-33010 | 1 Aveva | 1 System Platform | 2025-04-16 | 7.5 High |
An exception is thrown from a function in AVEVA System Platform versions 2017 through 2020 R2 P01, but it is not caught, which may cause a denial-of-service condition. | ||||
CVE-2020-25160 | 1 Bbraun | 2 Datamodule Compactplus, Spacecom | 2025-04-16 | 6.8 Medium |
Improper access controls in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enables attackers to extract and tamper with the devices network configuration. | ||||
CVE-2021-38425 | 1 Eprosima | 1 Fast Dds | 2025-04-16 | 7.5 High |
eProsima Fast DDS versions prior to 2.4.0 (#2269) are susceptible to exploitation when an attacker sends a specially crafted packet to flood a target device with unwanted traffic, which may result in a denial-of-service condition and information exposure. | ||||
CVE-2021-27444 | 1 Weintek | 32 Cmt-ctrl01, Cmt-ctrl01 Firmware, Cmt-fhd and 29 more | 2025-04-16 | 9.8 Critical |
The Weintek cMT product line is vulnerable to various improper access controls, which may allow an unauthenticated attacker to remotely access and download sensitive information and perform administrative actions on behalf of a legitimate administrator. | ||||
CVE-2022-1667 | 1 Secheron | 2 Sepcos Control And Protection Relay, Sepcos Control And Protection Relay Firmware | 2025-04-16 | 7.5 High |
Client-side JavaScript controls may be bypassed by directly running a JS function to reboot the PLC (e.g., from the browser console) or by loading the corresponding, browser accessible PHP script |