Filtered by vendor Tenda
Subscriptions
Filtered by product Ac18 Firmware
Subscriptions
Total
63 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-2485 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-02-13 | 8.8 High |
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-57583 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-02-04 | 9.8 Critical |
Tenda AC18 V15.03.05.19 was discovered to contain a command injection vulnerability via the usbName parameter in the formSetSambaConf function. | ||||
CVE-2024-57575 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-02-03 | 9.8 Critical |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. | ||||
CVE-2023-30135 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-29 | 9.8 Critical |
Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName parameter in the setUsbUnload function. | ||||
CVE-2024-2546 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-27 | 8.8 High |
A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2547 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-27 | 8.8 High |
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2558 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-27 | 8.8 High |
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2559 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-27 | 4.3 Medium |
A vulnerability classified as problematic has been found in Tenda AC18 15.03.05.05. Affected is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257058 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2560 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-22 | 4.3 Medium |
A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2489 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-14 | 8.8 High |
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2490 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-14 | 8.8 High |
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2488 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-14 | 8.8 High |
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2487 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-14 | 8.8 High |
A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2486 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-14 | 8.8 High |
A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability. | ||||
CVE-2024-2854 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2024-11-21 | 6.3 Medium |
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-28553 | 1 Tenda | 1 Ac18 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function. | ||||
CVE-2024-28537 | 1 Tenda | 1 Ac18 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the page parameter of fromNatStaticSetting function. | ||||
CVE-2024-28535 | 1 Tenda | 1 Ac18 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function. | ||||
CVE-2023-38823 | 1 Tenda | 8 Ac18, Ac18 Firmware, Ac19 and 5 more | 2024-11-21 | 9.8 Critical |
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd. | ||||
CVE-2023-24170 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/fromSetWirelessRepeat. |