Search Results (18 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-50926 1 Wago 2 750-8212, Pfc200 2026-04-15 9.8 Critical
WAGO 750-8212 PFC200 G2 2ETH RS firmware contains a privilege escalation vulnerability that allows attackers to manipulate user session cookies. Attackers can modify the cookie's 'name' and 'roles' parameters to elevate from ordinary user to administrative privileges without authentication.
CVE-2021-30187 2 Codesys, Wago 55 Runtime Toolkit, 750-8202, 750-8202 Firmware and 52 more 2025-08-15 5.3 Medium
CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command.
CVE-2021-30195 2 Codesys, Wago 56 Plcwinnt, Runtime Toolkit, 750-8202 and 53 more 2025-08-15 7.5 High
CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation.
CVE-2021-34583 2 Codesys, Wago 55 Codesys, 750-8202, 750-8202 Firmware and 52 more 2025-08-15 7.5 High
Crafted web server requests may cause a heap-based buffer overflow and could therefore trigger a denial-of- service condition due to a crash in the CODESYS V2 web server prior to V1.1.9.22.
CVE-2021-34584 2 Codesys, Wago 55 Codesys, 750-8202, 750-8202 Firmware and 52 more 2025-08-15 9.1 Critical
Crafted web server requests can be utilised to read partial stack or heap memory or may trigger a denial-of- service condition due to a crash in the CODESYS V2 web server prior to V1.1.9.22.
CVE-2021-34585 2 Codesys, Wago 55 Codesys, 750-8202, 750-8202 Firmware and 52 more 2025-08-15 7.5 High
In the CODESYS V2 web server prior to V1.1.9.22 crafted web server requests can trigger a parser error. Since the parser result is not checked under all conditions, a pointer dereference with an invalid address can occur. This leads to a denial of service situation.
CVE-2021-34586 2 Codesys, Wago 55 Codesys, 750-8202, 750-8202 Firmware and 52 more 2025-08-15 7.5 High
In the CODESYS V2 web server prior to V1.1.9.22 crafted web server requests may cause a Null pointer dereference in the CODESYS web server and may result in a denial-of-service condition.
CVE-2021-34593 2 Codesys, Wago 28 Plcwinnt, Runtime Toolkit, 750-8202 and 25 more 2025-08-15 7.5 High
In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC.
CVE-2021-34595 2 Codesys, Wago 57 Codesys, Plcwinnt, Runtime Toolkit and 54 more 2025-08-15 8.1 High
A crafted request with invalid offsets may cause an out-of-bounds read or write access in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition or local memory overwrite.
CVE-2021-34596 2 Codesys, Wago 57 Codesys, Plcwinnt, Runtime Toolkit and 54 more 2025-08-15 6.5 Medium
A crafted request may cause a read access to an uninitialized pointer in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition.
CVE-2021-21000 1 Wago 54 750-8202, 750-8202 Firmware, 750-8203 and 51 more 2025-08-15 5.3 Medium
On WAGO PFC200 devices in different firmware versions with special crafted packets an attacker with network access to the device could cause a denial of service for the login service of the runtime.
CVE-2021-21001 1 Wago 54 750-8202, 750-8202 Firmware, 750-8203 and 51 more 2025-08-15 9.1 Critical
On WAGO PFC200 devices in different firmware versions with special crafted packets an authorised attacker with network access to the device can access the file system with higher privileges.
CVE-2021-30186 2 Codesys, Wago 56 Plcwinnt, Runtime Toolkit, 750-8202 and 53 more 2025-08-15 7.5 High
CODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow.
CVE-2022-3281 1 Wago 156 750-8100, 750-8100 Firmware, 750-8101 and 153 more 2025-05-10 7.5 High
WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter.
CVE-2020-12069 4 Codesys, Festo, Pilz and 1 more 114 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 111 more 2025-05-05 7.8 High
In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device.
CVE-2023-1620 1 Wago 152 750-331, 750-331 Firmware, 750-8202 and 149 more 2024-11-21 4.9 Medium
Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a specifically crafted packet to the CODESYS V2 runtime.
CVE-2023-1619 1 Wago 152 750-331, 750-331 Firmware, 750-8202 and 149 more 2024-11-21 4.9 Medium
Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a malformed packet.
CVE-2020-12522 1 Wago 42 750-8101\/025-000, 750-8102\/025-000, 750-8202\/000-012 and 39 more 2024-11-21 10 Critical
The reported vulnerability allows an attacker who has network access to the device to execute code with specially crafted packets in WAGO Series PFC 100 (750-81xx/xxx-xxx), Series PFC 200 (750-82xx/xxx-xxx), Series Wago Touch Panel 600 Standard Line (762-4xxx), Series Wago Touch Panel 600 Advanced Line (762-5xxx), Series Wago Touch Panel 600 Marine Line (762-6xxx) with firmware versions <=FW10.