Filtered by vendor Siemens Subscriptions
Total 1930 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2011-4875 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2024-11-21 N/A
Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings.
CVE-2011-4532 1 Siemens 1 Automation License Manager 2024-11-21 N/A
Absolute path traversal vulnerability in the ALMListView.ALMListCtrl ActiveX control in almaxcx.dll in the graphical user interface in Siemens Automation License Manager (ALM) 2.0 through 5.1+SP1+Upd2 allows remote attackers to overwrite arbitrary files via the Save method.
CVE-2011-4531 1 Siemens 1 Automation License Manager 2024-11-21 N/A
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allows remote attackers to cause a denial of service (NULL pointer dereference and daemon crash) via crafted content in a (1) get_target_ocx_param or (2) send_target_ocx_param command.
CVE-2011-4530 1 Siemens 1 Automation License Manager 2024-11-21 N/A
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 does not properly copy fields obtained from clients, which allows remote attackers to cause a denial of service (exception and daemon crash) via long fields, as demonstrated by fields to the (1) open_session->workstation->NAME or (2) grant->VERSION function.
CVE-2011-4529 1 Siemens 1 Automation License Manager 2024-11-21 N/A
Multiple buffer overflows in Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allow remote attackers to execute arbitrary code via a long serialid field in an _licensekey command, as demonstrated by the (1) check_licensekey or (2) read_licensekey command.
CVE-2011-4515 1 Siemens 1 Wincc Tia Portal 2024-11-21 N/A
Siemens WinCC (TIA Portal) 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging (1) physical access or (2) Sm@rt Server access.
CVE-2011-4514 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2024-11-21 N/A
The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session.
CVE-2011-4513 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2024-11-21 N/A
Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader.
CVE-2011-4512 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2024-11-21 N/A
CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors.
CVE-2011-4511 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2024-11-21 N/A
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510.
CVE-2011-4510 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2024-11-21 N/A
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511.
CVE-2011-4509 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2024-11-21 N/A
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests.
CVE-2011-4508 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2024-11-21 N/A
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie.
CVE-2011-4056 1 Siemens 1 Tecnomatix Factorylink 2024-11-21 N/A
An unspecified ActiveX control in ActBar.ocx in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to create or overwrite arbitrary files via the save method.
CVE-2011-4055 1 Siemens 1 Tecnomatix Factorylink 2024-11-21 N/A
Buffer overflow in the WebClient ActiveX control in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to execute arbitrary code via a long string in a parameter associated with the location URL.
CVE-2011-3389 9 Canonical, Debian, Google and 6 more 21 Ubuntu Linux, Debian Linux, Chrome and 18 more 2024-11-21 N/A
The SSL protocol, as used in certain configurations in Microsoft Windows and Microsoft Internet Explorer, Mozilla Firefox, Google Chrome, Opera, and other products, encrypts data by using CBC mode with chained initialization vectors, which allows man-in-the-middle attackers to obtain plaintext HTTP headers via a blockwise chosen-boundary attack (BCBA) on an HTTPS session, in conjunction with JavaScript code that uses (1) the HTML5 WebSocket API, (2) the Java URLConnection API, or (3) the Silverlight WebClient API, aka a "BEAST" attack.
CVE-2011-3321 1 Siemens 2 Simatic Wincc Flexible Runtime, Simatic Wincc Runtime 2024-11-21 N/A
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.
CVE-2010-2772 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2024-11-21 7.8 High
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
CVE-2009-3322 1 Siemens 1 Gigaset Se361 Wlan Router 2024-11-21 N/A
The Siemens Gigaset SE361 WLAN router allows remote attackers to cause a denial of service (device reboot) via a flood of crafted TCP packets to port 1723.
CVE-2009-1152 1 Siemens 1 Gigaset Se461 Wimax Router 2024-11-21 N/A
Siemens Gigaset SE461 WiMAX router 1.5-BL024.9.6401, and possibly other versions, allows remote attackers to cause a denial of service (device restart and loss of configuration) by connecting to TCP port 53, then closing the connection.