| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Buffer Overflow vulnerability in UTT nv518G nv518GV3v3.2.7-210919-161313 allows a remote attacker to cause a denial of service via the gohead/sub_487330 component |
| Notepad3 through 6.25.822.1 contains a DLL search-order hijacking vulnerability in the About-dialog code path in src/Notepad3.c. The application calls LoadLibrary(L"MSFTEDIT.DLL") with a bare DLL name, which allows a local attacker to place a malicious MSFTEDIT.DLL in the application directory or another preferred DLL search location and achieve arbitrary code execution in the context of the user when the About dialog is opened. |
| ardupilot through Plane-4.6.3 was found to contain an out-of-bounds read issue in libraries/GCS_MAVLink/GCS_serial_control.cpp in GCS_MAVLINK::handle_serial_control(). |
| A malicious actor with access to the network and under certain network configurations could exploit an Improper Access Control vulnerability found in certain devices running UniFi OS to make unauthorized changes to such UniFi OS devices. |
| A malicious actor with access to the network and under certain conditions could exploit an Incorrect Authorization vulnerability found in UniFi Network Application to persist privileges within UniFi Network Application after such access had been removed. |
| In Eclipse Theia since version 1.26.0, the backend /services/request-service RPC accepts an attacker-controlled URL from any client connected to the standard /services messaging endpoint, performs the HTTP request server-side, and returns the full response body to the caller.
Because the destination URL is neither validated nor allowlisted, a remote attacker with access to the Theia service connection can issue server-side HTTP requests to localhost or other backend-reachable hosts and read their responses, exposing internal administrative endpoints, cloud instance metadata services, and other resources that are intentionally outside the browser network boundary.
The vulnerability affects deployments where the Theia service connection is reachable by untrusted users (for example, multi-tenant or publicly-reachable Theia deployments). |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper limitation of a pathname to a restricted directory ('path traversal') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure. |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper access control vulnerability in the RBAC. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to information tampering. |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution. |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure. |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an insertion of sensitive information into log file vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure. |
| ** UNSUPPORTED WHEN ASSIGNED ** Incorrect Authorization vulnerability in Apache Submarine Server Core.
This issue affects Apache Submarine Server Core: from 0.8.0.
An attacker can bypass authentication by sending specially crafted REST requests.
As this project is retired, we do not plan to release a version that fixes this issue. Users are recommended to find an alternative or restrict access to the instance to trusted users.
NOTE: This vulnerability only affects products that are no longer supported by the maintainer. |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of externally-controlled format string vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure and denial of service. |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution. |
| A flaw was identified in Argo CD, the GitOps engine used by Red Hat OpenShift GitOps, that could allow an unauthenticated attacker with network access to the Argo CD repo-server to achieve remote code execution. Under certain conditions, the attacker may then manipulate cached data to deploy malicious Kubernetes resources to managed clusters, potentially resulting in complete cluster compromise. |
| The fix for CVE-2026-0716 (commit 6ff7ef0, libsoup 3.6.6) placed the integer overflow guard inside the if (masked) block, leaving unmasked server-to-client frames unprotected. A malicious WebSocket server can send a crafted unmasked frame with a payload length near UINT64_MAX to trigger an OOB read in a libsoup-based client when max_incoming_payload_size is set to 0. |
| A vulnerability has been identified in Mendix Runtime (All versions). Mendix documentation for access rules does not adequately describe the special behavior of the System.User entity, leaving developers without sufficient guidance to configure access rules securely. This documentation gap may lead application developers to unknowingly apply overly permissive access rules to System.User, resulting in unintended exposure of sensitive user data or privilege escalation within deployed Mendix applications. |
| A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information. |
| myVesta is affected by an authenticated remote code execution vulnerability. Low privileged users can insert arbitrary commands as a part of the v_ftp_user parameter when deleting FTP usernames. This could result in the execution of commands as the admin user or takevoer of the admin user in myVesta. |
| mrubyc through release3.4.1 was found to contain an out-of-bounds read in builtin missing-method lookup inside mrbc_find_method(). |