Filtered by vendor Siemens Subscriptions
Total 1930 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2019-13944 1 Siemens 6 En100 Ethernet Module, En100 Ethernet Module With Firmware Variant Dnp3 Tcp, En100 Ethernet Module With Firmware Variant Iec104 and 3 more 2024-11-21 5.3 Medium
A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). A vulnerability in the integrated web server of the affected devices could allow unauthorized attackers to obtain sensitive information about the device, including logs and configurations. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13943 1 Siemens 6 En100 Ethernet Module, En100 Ethernet Module With Firmware Variant Dnp3 Tcp, En100 Ethernet Module With Firmware Variant Iec104 and 3 more 2024-11-21 6.1 Medium
A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing the application to behave in unexpected ways for legitimate users. Successful exploitation does not require for an attacker to be authenticated to the web interface. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security. vulnerability was known.
CVE-2019-13942 1 Siemens 6 En100 Ethernet Module, En100 Ethernet Module With Firmware Variant Dnp3 Tcp, En100 Ethernet Module With Firmware Variant Iec104 and 3 more 2024-11-21 7.5 High
A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). An unauthorized user could exploit a buffer overflow vulnerability in the webserver. Specially crafted packets sent could cause a Denial-of-Service condition and if certain conditions are met, the affected devices must be restarted manually to fully recover. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13941 1 Siemens 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more 2024-11-21 7.5 High
A vulnerability has been identified in OZW672 (All versions < V10.00), OZW772 (All versions < V10.00). Vulnerable versions of OZW Web Server use predictable path names for project files that legitimately authenticated users have created by using the application's export function. By accessing a specific uniform resource locator on the web server, a remote attacker could be able to download a project file without prior authentication. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected system. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system.
CVE-2019-13940 1 Siemens 47 S7-1200 Cpu 1211c, S7-1200 Cpu 1211c Firmware, S7-1200 Cpu 1212c and 44 more 2024-11-21 5.3 Medium
A vulnerability has been identified in SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.X.17), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.1), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX 2010 (All versions), SIMATIC WinAC RTX F 2010 (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.X.17), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.X.17), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.X.17). Affected devices contain a vulnerability that could cause a denial of service condition of the web server by sending specially crafted HTTP requests to ports 80/tcp and 443/tcp. Beyond the web service, no other functions or interfaces are affected by the denial of service condition.
CVE-2019-13939 1 Siemens 46 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 43 more 2024-11-21 7.1 High
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus Source Code (All versions). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value.
CVE-2019-13936 1 Siemens 1 Polarion 2024-11-21 3.5 Low
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a persistent XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
CVE-2019-13935 1 Siemens 1 Polarion 2024-11-21 3.5 Low
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
CVE-2019-13934 1 Siemens 1 Polarion 2024-11-21 3.5 Low
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
CVE-2019-13933 1 Siemens 14 Scalance X-200rna, Scalance X-200rna Firmware, Scalance X-300 and 11 more 2024-11-21 8.6 High
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13932 1 Siemens 1 Xhq 2024-11-21 9.1 Critical
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web application requests could be manipulated, causing the the application to behave in unexpected ways for legitimate users. Successful exploitation does not require for an attacker to be authenticated. A successful attack could allow the import of scripts or generation of malicious links. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13931 1 Siemens 1 Xhq 2024-11-21 5.4 Medium
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow for an an attacker to craft the input in a form that is not expected, causing the application to behave in unexpected ways for legitimate users. Successful exploitation requires for an attacker to be authenticated to the web interface. A successful attack could cause the application to have unexpected behavior. This could allow the attacker to modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13930 1 Siemens 1 Xhq 2024-11-21 8.1 High
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13929 1 Siemens 1 Simatic It Uadm 2024-11-21 6.5 Medium
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13927 1 Siemens 32 Pxa30-w0, Pxa30-w0 Firmware, Pxa30-w1 and 29 more 2024-11-21 5.3 Medium
A vulnerability has been identified in Desigo PX automation controllers PXC00-E.D, PXC50-E.D, PXC100-E.D, PXC200-E.D with Desigo PX Web modules PXA40-W0, PXA40-W1, PXA40-W2 (All firmware versions < V6.00.320), Desigo PX automation controllers PXC00-U, PXC64-U, PXC128-U with Desigo PX Web modules PXA30-W0, PXA30-W1, PXA30-W2 (All firmware versions < V6.00.320), Desigo PX automation controllers PXC22.1-E.D, PXC36-E.D, PXC36.1-E.D with activated web server (All firmware versions < V6.00.320). The device contains a vulnerability that could allow an attacker to cause a denial of service condition on the device's web server by sending a specially crafted HTTP message to the web server port (tcp/80). The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device's web service. While the device itself stays operational, the web server responds with HTTP status code 404 (Not found) to any further request. A reboot is required to recover the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13926 1 Siemens 8 Scalance S602, Scalance S602 Firmware, Scalance S612 and 5 more 2024-11-21 7.5 High
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.
CVE-2019-13925 1 Siemens 8 Scalance S602, Scalance S602 Firmware, Scalance S612 and 5 more 2024-11-21 7.5 High
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server.
CVE-2019-13924 1 Siemens 16 Scalance X-200irt, Scalance X-200irt Firmware, Scalance X-300 and 13 more 2024-11-21 5.4 Medium
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
CVE-2019-13923 1 Siemens 2 Ie\/wsn-pa Link Wirelesshart Gateway, Ie\/wsn-pa Link Wirelesshart Gateway Firmware 2024-11-21 9.6 Critical
A vulnerability has been identified in IE/WSN-PA Link WirelessHART Gateway (All versions). The integrated configuration web server of the affected device could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known.
CVE-2019-13922 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 2.7 Low
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known.