Search Results (1743 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2014-125121 1 Arraynetworks 2 Vapv, Vxag 2026-04-15 N/A
Array Networks vAPV (version 8.3.2.17) and vxAG (version 9.2.0.34) appliances are affected by a privilege escalation vulnerability caused by a combination of hardcoded SSH credentials (or SSH private key) and insecure permissions on a startup script. The devices ship with a default SSH login or a hardcoded DSA private key, allowing an attacker to authenticate remotely with limited privileges. Once authenticated, an attacker can overwrite the world-writable /ca/bin/monitor.sh script with arbitrary commands. Since this script is executed with elevated privileges through the backend binary, enabling the debug monitor via backend -c "debug monitor on" triggers execution of the attacker's payload as root. This allows full system compromise.
CVE-2024-49385 1 Acronis 1 True Image 2026-04-15 N/A
Sensitive information disclosure due to insecure folder permissions. The following products are affected: Acronis True Image (Windows) before build 41736, Acronis True Image OEM (Windows) before build 42575.
CVE-2024-45841 2026-04-15 N/A
Incorrect permission assignment for critical resource issue exists in UD-LT1 firmware Ver.2.1.9 and earlier and UD-LT1/EX firmware Ver.2.1.9 and earlier. If an attacker with the guest account of the affected products accesses a specific file, the information containing credentials may be obtained.
CVE-2024-37574 2026-04-15 8.2 High
The GriceMobile com.grice.call application 4.5.2 for Android enables any installed application (with no permissions) to place phone calls without user interaction by sending a crafted intent via the com.iui.mobile.presentation.MobileActivity.
CVE-2025-54497 1 Cognex 2 In-sight Camera Firmware, In-sight Explorer 2026-04-15 8.1 High
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges can successfully invoke the SetSerialPort functionality to modify relevant device properties (such as serial interface settings), contradicting the security model proposed in the user manual.
CVE-2025-23285 1 Nvidia 1 Virtual Gpu Manager 2026-04-15 5.5 Medium
NVIDIA vGPU software contains a vulnerability in the Virtual GPU Manager, where it allows a guest to access global resources. A successful exploit of this vulnerability might lead to denial of service.
CVE-2025-24009 2026-04-15 5.9 Medium
A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not require authentication to access critical resources. An attacker with network access could retrieve sensitive information from certain data records, including obfuscated safety passwords.
CVE-2025-50675 2026-04-15 7.8 High
GPMAW 14, a bioinformatics software, has a critical vulnerability related to insecure file permissions in its installation directory. The directory is accessible with full read, write, and execute permissions for all users, allowing unprivileged users to manipulate files within the directory, including executable files like GPMAW3.exe, Fragment.exe, and the uninstaller GPsetup64_17028.exe. An attacker with user-level access can exploit this misconfiguration by replacing or modifying the uninstaller (GPsetup64_17028.exe) with a malicious version. While the application itself runs in the user's context, the uninstaller is typically executed with administrative privileges when an administrator attempts to uninstall the software. By exploiting this flaw, an attacker could gain administrative privileges and execute arbitrary code in the context of the admin, resulting in privilege escalation.
CVE-2024-39967 2026-04-15 6.5 Medium
Insecure permissions in Aginode GigaSwitch v5 allows attackers to access sensitive information via using the SCP command.
CVE-2019-25343 1 Vm3max 1 Nextvpn 2026-04-15 7.8 High
NextVPN 4.10 contains an insecure file permissions vulnerability that allows local users to modify executable files with full access rights. Attackers can replace system executables with malicious files to gain SYSTEM or Administrator privileges through unauthorized file modification.
CVE-2024-10526 1 Rapid7 1 Velociraptor 2026-04-15 N/A
Rapid7 Velociraptor MSI Installer versions below 0.73.3 suffer from a vulnerability whereby it creates the installation directory with WRITE_DACL permission to the BUILTIN\\Users group. This allows local users who are not administrators to grant themselves the Full Control permission on Velociraptor's files. By modifying Velociraptor's files, local users can subvert the binary and cause the Velociraptor service to execute arbitrary code as the SYSTEM user, or to replace the Velociraptor binary completely.  This issue is fixed in version 0.73.3.
CVE-2024-33499 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected application assigns incorrect permissions to a user management component. This could allow a privileged attacker to escalate their privileges from the Administrators group to the Systemadministrator group.
CVE-2025-34025 1 Versa 1 Concerto 2026-04-15 N/A
The Versa Concerto SD-WAN orchestration platform is vulnerable to an privileges escalation and container escape vulnerability caused by unsafe default mounting of host binary paths that allow the container to modify host paths. The escape can be used to trigger remote code execution or direct host access depending on the host operating system configuration.This issue is known to affect Concerto from 12.1.2 through 12.2.0. Additional versions may be vulnerable.
CVE-2025-10541 1 Imonitor 1 Imonitor Eam 2026-04-15 7.8 High
iMonitor EAM 9.6394 installs a system service (eamusbsrv64.exe) that runs with NT AUTHORITY\SYSTEM privileges. This service includes an insecure update mechanism that automatically loads files placed in the C:\sysupdate\ directory during startup. Because any local user can create and write to this directory, an attacker can place malicious DLLs or executables in it. Upon service restart, the files are moved to the application’s installation path and executed with SYSTEM privileges, leading to privilege escalation.
CVE-2024-27108 2026-04-15 6.8 Medium
Non privileged access to critical file vulnerability in GE HealthCare EchoPAC products
CVE-2025-31702 1 Dahua 2 Ipc, Sd 2026-04-15 6.8 Medium
A vulnerability exists in certain Dahua embedded products. Third-party malicious attacker with obtained normal user credentials could exploit the vulnerability to access certain data which are restricted to admin privileges, such as system-sensitive files through specific HTTP request. This may cause tampering with admin password, leading to privilege escalation. Systems with only admin account are not affected.
CVE-2025-23403 1 Siemens 2 Simatic Ipc Diagbase, Simatic Ipc Diagmonitor 2026-04-15 7 High
A vulnerability has been identified in SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions). The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to privilege escalation or bypassing endpoint protection and other security measures.
CVE-2024-36137 1 Redhat 1 Enterprise Linux 2026-04-15 3.9 Low
A vulnerability has been identified in Node.js, affecting users of the experimental permission model when the --allow-fs-write flag is used. Node.js Permission Model do not operate on file descriptors, however, operations such as fs.fchown or fs.fchmod can use a "read-only" file descriptor to change the owner and permissions of a file.
CVE-2025-2098 2026-04-15 N/A
Fast CAD Reader application on MacOS was found to be installed with incorrect file permissions (rwxrwxrwx). This is inconsistent with standard macOS security practices, where applications should have drwxr-xr-x permissions. Incorrect permissions allow for Dylib Hijacking. Guest account, other users and applications can exploit this vulnerability for privilege escalation. This issue affects Fast CAD Reader in possibly all versions since the vendor has not responded to our messages. The tested version was 4.1.5
CVE-2025-0758 1 Hitachi 1 Vantara Pentaho Business Analytics Server 2026-04-15 6.1 Medium
Overview  The product specifies permissions for a security-critical resource in a way that allows that resource to be read or modified by unintended actors. (CWE-732)  Description  Hitachi Vantara Pentaho Business Analytics Server prior to versions 10.2.0.2, including 9.3.x and 8.3.x, is installed with Karaf JMX beans enabled and accessible by default.  Impact  When the vulnerability is leveraged, a user with local execution privileges can access functionality exposed by Karaf beans contained in the product.