Filtered by vendor Deltaww Subscriptions
Total 234 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-46690 1 Deltaww 1 Infrasuite Device Master 2024-11-21 8.8 High
In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an attacker to write to any file to any location of the filesystem, which could lead to remote code execution.
CVE-2023-43824 1 Deltaww 1 Dopsoft 2024-11-21 8.8 High
A stack based buffer overflow exists in Delta Electronics Delta Industrial Automation DOPSoft when parsing the wTitleTextLen field of a DPS file. A remote, unauthenticated attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve remote code execution.
CVE-2023-43823 1 Deltaww 1 Dopsoft 2024-11-21 8.8 High
A stack based buffer overflow exists in Delta Electronics Delta Industrial Automation DOPSoft when parsing the wTTitleLen field of a DPS file. A remote, unauthenticated attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve remote code execution.
CVE-2023-43822 1 Deltaww 1 Dopsoft 2024-11-21 8.8 High
A stack based buffer overflow exists in Delta Electronics Delta Industrial Automation DOPSoft when parsing the wLogTitlesTimeLen field of a DPS file. A remote, unauthenticated attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve remote code execution.
CVE-2023-43821 1 Deltaww 1 Dopsoft 2024-11-21 8.8 High
A stack based buffer overflow exists in Delta Electronics Delta Industrial Automation DOPSoft when parsing the wLogTitlesActionLen field of a DPS file. A remote, unauthenticated attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve remote code execution.
CVE-2023-43820 1 Deltaww 1 Dopsoft 2024-11-21 8.8 High
A stack based buffer overflow exists in Delta Electronics Delta Industrial Automation DOPSoft when parsing the wLogTitlesPrevValueLen field of a DPS file. A remote, unauthenticated attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve remote code execution.
CVE-2023-43819 1 Deltaww 1 Dopsoft 2024-11-21 8.8 High
A stack based buffer overflow exists in Delta Electronics Delta Industrial Automation DOPSoft when parsing the InitialMacroLen field of a DPS file. A remote, unauthenticated attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve remote code execution.
CVE-2023-43818 1 Deltaww 1 Dopsoft 2024-11-21 8.8 High
A buffer overflow exists in Delta Electronics Delta Industrial Automation DOPSoft. A remote, unauthenticated attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve remote code execution.
CVE-2023-43817 1 Deltaww 1 Dopsoft 2024-11-21 7.5 High
A buffer overflow exists in Delta Electronics Delta Industrial Automation DOPSoft version 2 when parsing the wMailContentLen field of a DPS file. An anonymous attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve code execution.
CVE-2023-43816 1 Deltaww 1 Dopsoft 2024-11-21 6.3 Medium
A buffer overflow vulnerability exists in Delta Electronics Delta Industrial Automation DOPSoft version 2 when parsing the wKPFStringLen field of a DPS file. An anonymous attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve code execution.
CVE-2023-43815 1 Deltaww 1 Dopsoft 2024-11-21 7.1 High
A buffer overflow vulnerability exists in Delta Electronics Delta Industrial Automation DOPSoft version 2 when parsing the wScreenDESCTextLen field of a DPS file. An anonymous attacker can exploit this vulnerability by enticing a user to open a specially crafted DPS file to achieve code execution.
CVE-2023-39226 1 Deltaww 1 Infrasuite Device Master 2024-11-21 9.8 Critical
In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute arbitrary code through a single UDP packet.
CVE-2023-34347 1 Deltaww 1 Infrasuite Device Master 2024-11-21 9.8 Critical
​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.
CVE-2022-43775 1 Deltaww 1 Diaenergie 2024-11-21 9.8 Critical
The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system.
CVE-2022-43774 1 Deltaww 1 Diaenergie 2024-11-21 9.8 Critical
The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system.
CVE-2022-43457 1 Deltaww 1 Diaenergie 2024-11-21 8.8 High
SQL Injection in HandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
CVE-2022-3214 1 Deltaww 1 Diaenergie 2024-11-21 9.8 Critical
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to  1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution.
CVE-2022-33005 1 Deltaww 1 Diaenergie 2024-11-21 6.1 Medium
A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1.08.00 allows attackers to execute arbitrary web scripts via a crafted payload injected into the Name text field.
CVE-2021-44544 1 Deltaww 1 Diaenergie 2024-11-21 7.5 High
DIAEnergie Version 1.7.5 and prior is vulnerable to multiple cross-site scripting vulnerabilities when arbitrary code is injected into the parameter “name” of the script “HandlerEnergyType.ashx”.
CVE-2021-44471 1 Deltaww 1 Diaenergie 2024-11-21 7.5 High
DIAEnergie Version 1.7.5 and prior is vulnerable to stored cross-site scripting when an unauthenticated user injects arbitrary code into the parameter “name” of the script “DIAE_HandlerAlarmGroup.ashx”.