| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Settings module in Websense Triton Unified Security Center 7.7.3 before Hotfix 31, Web Filter 7.7.3 before Hotfix 31, Web Security 7.7.3 before Hotfix 31, Web Security Gateway 7.7.3 before Hotfix 31, and Web Security Gateway Anywhere 7.7.3 before Hotfix 31 allows remote authenticated users to read cleartext passwords by replacing type="password" with type="text" in an INPUT element in the (1) Log Database or (2) User Directories component. |
| The client in IBM Cognos TM1 9.5.2.3 before IF5, 10.1.1.2 before IF1, 10.2.0.2 before IF1, and 10.2.2.0 before IF1 stores obfuscated passwords in memory, which allows remote authenticated users to obtain sensitive cleartext information via an unspecified security tool. |
| Apache Cordova Android before 3.5.1 allows remote attackers to bypass the HTTP whitelist and connect to arbitrary servers by using JavaScript to open WebSocket connections through WebView. |
| Foscam IP camera 11.37.2.49 and other versions, when using the Foscam DynDNS option, generates credentials based on predictable camera subdomain names, which allows remote attackers to spoof or hijack arbitrary cameras and conduct other attacks by modifying arbitrary camera records in the Foscam DNS server. |
| GE Healthcare Discovery 530C has a password of #bigguy1 for the (1) acqservice user and (2) wsservice user of the Xeleris System, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. |
| GE Healthcare Optima CT680, CT540, CT640, and CT520 has a default password of #bigguy for the root user, which has unspecified impact and attack vectors. |
| The HIPAA configuration interface in GE Healthcare Optima MR360 has a password of (1) operator for the root account, (2) adw2.0 for the admin account, and (3) adw2.0 for the sdc account, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value. |
| GE Healthcare Optima MR360 does not require authentication for the HIPAA emergency login procedure, which allows physically proximate users to gain access via an arbitrary username in the Emergency Login screen. NOTE: this might not qualify for inclusion in CVE if unauthenticated emergency access is part of the intended security policy of the product, can be controlled by the system administrator, and is not enabled by default. |
| GE Healthcare CADStream Server has a default password of confirma for the admin user, which has unspecified impact and attack vectors. |
| The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. |
| GE Healthcare Precision MPi has a password of (1) orion for the serviceapp user, (2) orion for the clinical operator user, and (3) PlatinumOne for the administrator user, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value. |
| SolarWinds Log and Event Manager before 6.0 uses "static" credentials, which makes it easier for remote attackers to obtain access to the database and execute arbitrary code via unspecified vectors, related to HyperSQL. |
| IBM Security Access Manager for Mobile 8.x before 8.0.1 and Security Access Manager for Web 7.x before 7.0.0 FP10 and 8.x before 8.0.1 allow remote attackers to conduct clickjacking attacks via a crafted web site. |
| EMC PowerPath Virtual Appliance (aka vApp) before 2.0 has default passwords for the (1) emcupdate and (2) svcuser accounts, which makes it easier for remote attackers to obtain potentially sensitive information via a login session. |
| IBM WebSphere Application Server 7.x before 7.0.0.37, 8.0.x before 8.0.0.10, and 8.5.x before 8.5.5.4 allows remote attackers to conduct clickjacking attacks via a crafted web site. |
| M/Monit 3.3.2 and earlier does not verify the original password before changing passwords, which allows remote attackers to change the password of other users and gain privileges via the fullname and password parameters, a different vulnerability than CVE-2014-6409. |
| The MQXR service in WMQ Telemetry in IBM WebSphere MQ 7.1 before 7.1.0.7, 7.5 through 7.5.0.5, and 8.0 before 8.0.0.4 uses world-readable permissions for a cleartext file containing the SSL keystore password, which allows local users to obtain sensitive information by reading this file. |
| Inductive Automation Ignition 7.7.2 does not terminate a session upon a logout action, which allows remote attackers to bypass intended access restrictions by leveraging an unattended workstation. |
| Inductive Automation Ignition 7.7.2 allows remote authenticated users to bypass a brute-force protection mechanism by using different session ID values in a series of HTTP requests. |
| The (1) Removable Media and (2) CD and DVD encryption offsite access options (formerly Endpoint Encryption for Removable Media or EERM) in McAfee File and Removable Media Protection (FRP) 4.3.0.x, and Endpoint Encryption for Files and Folders (EEFF) 3.2.x through 4.2.x, uses a hard-coded salt, which makes it easier for local users to obtain passwords via a brute force attack. |