Filtered by vendor Philips Subscriptions
Total 107 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2017-3210 4 Fujitsu, Hp, Philips and 1 more 6 Displayview Click, Displayview Click Suite, Display Assistant and 3 more 2024-11-21 N/A
Applications developed using the Portrait Display SDK, versions 2.30 through 2.34, default to insecure configurations which allow arbitrary code execution. A number of applications developed using the Portrait Displays SDK do not use secure permissions when running. These applications run the component pdiservice.exe with NT AUTHORITY/SYSTEM permissions. This component is also read/writable by all Authenticated Users. This allows local authenticated attackers to run arbitrary code with SYSTEM privileges. The following applications have been identified by Portrait Displays as affected: Fujitsu DisplayView Click: Version 6.0 and 6.01. The issue was fixed in Version 6.3. Fujitsu DisplayView Click Suite: Version 5. The issue is addressed by patch in Version 5.9. HP Display Assistant: Version 2.1. The issue was fixed in Version 2.11. HP My Display: Version 2.0. The issue was fixed in Version 2.1. Philips Smart Control Premium: Versions 2.23, 2.25. The issue was fixed in Version 2.26.
CVE-2017-14797 1 Philips 2 Hue Bridge Bsb002, Hue Bridge Bsb002 Firmware 2024-11-21 N/A
Lack of Transport Encryption in the public API in Philips Hue Bridge BSB002 SW 1707040932 allows remote attackers to read API keys (and consequently bypass the pushlink protection mechanism, and obtain complete control of the connected accessories) by leveraging the ability to sniff HTTP traffic on the local intranet network.
CVE-2017-14111 1 Philips 2 Intellispace Cardiovascular, Xcelera 2024-11-21 N/A
The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements.
CVE-2015-2884 1 Philips 1 In.sight B120\\37 2024-11-21 N/A
Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi.
CVE-2015-2883 1 Philips 1 In.sight B120\\37 2024-11-21 N/A
Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php.
CVE-2015-2882 1 Philips 1 In.sight B120\\37 2024-11-21 N/A
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account.
CVE-2013-2808 1 Philips 4 Xper Flex Cardio, Xper Information Management Physiomonitoring 5, Xper Information Management Vascular Monitoring 5 and 1 more 2024-11-21 N/A
Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote attackers to execute arbitrary code via a crafted HTTP request to the Connect broker on TCP port 6000.