Filtered by vendor Ge Subscriptions
Total 128 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2019-6548 1 Ge 1 Ge Communicator 2024-11-21 9.8 Critical
GE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the database. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
CVE-2019-6546 1 Ge 1 Ge Communicator 2024-11-21 7.8 High
GE Communicator, all versions prior to 4.0.517, allows an attacker to place malicious files within the working directory of the program, which may allow an attacker to manipulate widgets and UI elements.
CVE-2019-6544 1 Ge 1 Ge Communicator 2024-11-21 5.6 Medium
GE Communicator, all versions prior to 4.0.517, has a service running with system privileges that may allow an unprivileged user to perform certain administrative actions, which may allow the execution of scheduled scripts with system administrator privileges. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
CVE-2019-18267 1 Ge 4 S2020, S2020 Firmware, S2020g and 1 more 2024-11-21 5.4 Medium
An issue was found in GE S2020/S2020G Fast Switch 61850, S2020/S2020G Fast Switch 61850 Versions 07A03 and prior. An attacker can inject arbitrary Javascript in a specially crafted HTTP request that may be reflected back in the HTTP response. The device is also vulnerable to a stored cross-site scripting vulnerability that may allow session hijacking, disclosure of sensitive data, cross-site request forgery (CSRF) attacks, and remote code execution.
CVE-2019-18255 1 Ge 1 Ifix 2024-11-21 5.5 Medium
HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through section objects. This may allow privilege escalation.
CVE-2019-18243 1 Ge 1 Ifix 2024-11-21 5.5 Medium
HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through the registry. This may allow privilege escalation.
CVE-2019-13559 1 Ge 1 Mark Vie Controll System 2024-11-21 7.8 High
GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go into applications requiring the GE commissioning engineer to change default configurations during the installation process. GE recommends that users reset controller passwords during installation in the operating environment.
CVE-2019-13554 1 Ge 1 Mark Vie Control System 2024-11-21 8.8 High
GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service.
CVE-2019-10966 1 Ge 8 Aespire 7100, Aespire 7100 Firmware, Aespire 7900 and 5 more 2024-11-21 5.3 Medium
In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms.
CVE-2018-8867 1 Ge 16 Pacsystems Cpu320, Pacsystems Cpu320 Firmware, Pacsystems Cru320 and 13 more 2024-11-21 N/A
In GE PACSystems RX3i CPE305/310 version 9.20 and prior, RX3i CPE330 version 9.21 and prior, RX3i CPE 400 version 9.30 and prior, PACSystems RSTi-EP CPE 100 all versions, and PACSystems CPU320/CRU320 RXi all versions, the device does not properly validate input, which could allow a remote attacker to send specially crafted packets causing the device to become unavailable.
CVE-2018-5475 1 Ge 2 D60 Line Distance Relay, D60 Line Distance Relay Firmware 2024-11-21 9.8 Critical
A Stack-based Buffer Overflow issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified, which may allow remote code execution.
CVE-2018-5473 1 Ge 2 D60 Line Distance Relay, D60 Line Distance Relay Firmware 2024-11-21 9.8 Critical
An Improper Restriction of Operations within the Bounds of a Memory Buffer issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. The SSH functions of the device are vulnerable to buffer overflow conditions that may allow a remote attacker to execute arbitrary code on the device.
CVE-2018-19003 1 Ge 6 Ex2100e, Ex2100e Firmware, Ls2100e and 3 more 2024-11-21 N/A
GE Mark VIe, EX2100e, EX2100e_Reg, and LS2100e Versions 03.03.28C to 05.02.04C, EX2100e All versions prior to v04.09.00C, EX2100e_Reg All versions prior to v04.09.00C, and LS2100e All versions prior to v04.09.00C The affected versions of the application have a path traversal vulnerability that fails to restrict the ability of an attacker to gain access to restricted information.
CVE-2018-17925 1 Ge 1 Ifix 2024-11-21 N/A
Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identified in the third-party ActiveX object provided to GE iFIX versions 2.0 - 5.8 by Gigasoft. Only the independent use of the Gigasoft charting package outside the iFIX product may expose users to the reported vulnerability. The reported method shown to impact Internet Explorer is not exposed in the iFIX product, nor is the core functionality of the iFIX product known to be impacted.
CVE-2018-15362 1 Ge 1 Cimplicity 2024-11-21 N/A
XXE in GE Proficy Cimplicity GDS versions 9.0 R2, 9.5, 10.0
CVE-2018-10615 1 Ge 1 Mds Pulsenet 2024-11-21 N/A
Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform.
CVE-2018-10613 1 Ge 1 Mds Pulsenet 2024-11-21 N/A
Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior.
CVE-2018-10611 1 Ge 1 Mds Pulsenet 2024-11-21 N/A
Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services.
CVE-2017-7908 2 Ge, Gigasoft 2 Ge Communicator, Proessentials 2024-11-21 N/A
A heap-based buffer overflow exists in the third-party product Gigasoft, v5 and prior, included in GE Communicator 3.15 and prior. A malicious HTML file that loads the ActiveX controls can trigger the vulnerability via unchecked function calls.
CVE-2017-7905 1 Ge 20 Multilin Sr 369 Motor Protection Relay, Multilin Sr 369 Motor Protection Relay Firmware, Multilin Sr 469 Motor Protection Relay and 17 more 2024-11-21 N/A
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.