Filtered by vendor Deltaww
Subscriptions
Total
233 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2022-41688 | 1 Deltaww | 1 Infrasuite Device Master | 2024-11-21 | 9.8 Critical |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group. | ||||
CVE-2022-41657 | 1 Deltaww | 1 Infrasuite Device Master | 2024-11-21 | 9.8 Critical |
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution. | ||||
CVE-2022-41651 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | 8.7 High |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the SetPF API. | ||||
CVE-2022-41644 | 1 Deltaww | 1 Infrasuite Device Master | 2024-11-21 | 8.8 High |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges. | ||||
CVE-2022-41629 | 1 Deltaww | 1 Infrasuite Device Master | 2024-11-21 | 7.5 High |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords. | ||||
CVE-2022-41555 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | 8.7 High |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutLineMessageSetting API. | ||||
CVE-2022-41133 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | 8.8 High |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | ||||
CVE-2022-40967 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | 8.8 High |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | ||||
CVE-2022-40965 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | 8.7 High |
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PostEnergyType API. | ||||
CVE-2022-40202 | 1 Deltaww | 1 Infrasuite Device Master | 2024-11-21 | 9.8 Critical |
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution. | ||||
CVE-2022-3214 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | 9.8 Critical |
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution. | ||||
CVE-2022-38142 | 1 Deltaww | 1 Infrasuite Device Master | 2024-11-21 | 9.8 Critical |
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization. | ||||
CVE-2022-33005 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | 6.1 Medium |
A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1.08.00 allows attackers to execute arbitrary web scripts via a crafted payload injected into the Name text field. | ||||
CVE-2022-2969 | 1 Deltaww | 1 Dialink | 2024-11-21 | 8.1 High |
Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory. | ||||
CVE-2022-2966 | 1 Deltaww | 1 Dopsoft | 2024-11-21 | 3.3 Low |
Out-of-bounds Read vulnerability in Delta Electronics DOPSoft.This issue affects DOPSoft: All Versions. | ||||
CVE-2022-2759 | 1 Deltaww | 1 Delta Robot Automation Studio | 2024-11-21 | 5.5 Medium |
Delta Electronics Delta Robot Automation Studio (DRAS) versions prior to 1.13.20 are affected by improper restrictions where the software processes an XML document that can contain XML entities with URIs that resolve to documents outside of the intended sphere of control, causing the product to embed incorrect documents into its output. This may allow an attacker to view sensitive documents and information on the affected host. | ||||
CVE-2022-2660 | 1 Deltaww | 1 Dialink | 2024-11-21 | 9.8 Critical |
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine. | ||||
CVE-2022-27175 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | 9.8 Critical |
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in GetCalcTagList. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
CVE-2022-26887 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | 9.8 Critical |
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_loopmapHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
CVE-2022-26839 | 1 Deltaww | 1 Diaenergie | 2024-11-21 | 7.8 High |
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to an incorrect default permission in the DIAEnergie application, which may allow an attacker to plant new files (such as DLLs) or replace existing executable files. |