| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Uninitialized Use in ANGLE in Google Chrome prior to 150.0.7871.46 allowed a remote attacker who had compromised the renderer process to potentially perform a sandbox escape via a crafted HTML page. (Chromium security severity: High) |
| Uninitialized Use in Dawn in Google Chrome on ChromeOS prior to 150.0.7871.46 allowed a remote attacker to obtain potentially sensitive information from process memory via a crafted HTML page. (Chromium security severity: Medium) |
| Uninitialized Use in Dawn in Google Chrome prior to 150.0.7871.46 allowed a remote attacker to obtain potentially sensitive information from process memory via a crafted HTML page. (Chromium security severity: Medium) |
| Use after free in ANGLE in Google Chrome prior to 150.0.7871.46 allowed a remote attacker to potentially perform a sandbox escape via a crafted HTML page. (Chromium security severity: High) |
| Use after free in Dawn in Google Chrome on Mac prior to 150.0.7871.46 allowed a remote attacker to potentially perform a sandbox escape via a crafted HTML page. (Chromium security severity: High) |
| Use after free in Skia in Google Chrome prior to 150.0.7871.46 allowed a remote attacker to potentially perform a sandbox escape via a crafted HTML page. (Chromium security severity: Critical) |
| Use after free in V8 in Google Chrome prior to 150.0.7871.46 allowed a remote attacker who convinced a user to engage in specific UI gestures to execute arbitrary code inside a sandbox via a crafted HTML page. (Chromium security severity: High) |
| Buffer Overflow vulnerability in UTT nv518G nv518GV3v3.2.7-210919-161313 allows a remote attacker to cause a denial of service via the gohead/sub_483ba0 component |
| A malicious actor with access to the network could exploit an Improper Input Validation vulnerability found in UniFi Network Application to execute a Denial of Service (DoS) attack on the application. |
| A malicious actor with access to the network could exploit a Path Traversal vulnerability found in certain devices running UniFi OS to bypass authentication of such UniFi OS devices or instances. |
| A malicious actor with access to the network and high privileges could exploit an Improper Access Control vulnerability found in UniFi Access Application to escalate privileges on the host device. |
| A malicious actor with access to the network could exploit an Improper Access Control vulnerability found in UniFi Connect Application to execute a Command Injection on the host device. |
| A malicious actor with access to the network,low privileges and under certain conditions could exploit an Improper Access Control vulnerability found in UniFi Network Application to escalate privileges within the UniFi Network Application. |
| A malicious actor with access to the network and low privileges could exploit an Improper Access Control vulnerability found in UniFi Talk Application to escalate privileges within the UniFi Talk Application. |
| In Eclipse Theia since version 1.26.0, the backend /services/request-service RPC accepts an attacker-controlled URL from any client connected to the standard /services messaging endpoint, performs the HTTP request server-side, and returns the full response body to the caller.
Because the destination URL is neither validated nor allowlisted, a remote attacker with access to the Theia service connection can issue server-side HTTP requests to localhost or other backend-reachable hosts and read their responses, exposing internal administrative endpoints, cloud instance metadata services, and other resources that are intentionally outside the browser network boundary.
The vulnerability affects deployments where the Theia service connection is reachable by untrusted users (for example, multi-tenant or publicly-reachable Theia deployments). |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper limitation of a pathname to a restricted directory ('path traversal') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure. |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an use of uninitialized resource vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure. |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an incorrect authorization vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized command execution. |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper link resolution before file access ('Link following') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information exposure. |
| Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an integer overflow or wraparound vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service. |