Search Results (3388 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-6895 2026-04-15 N/A
Insufficient authentication in user account management in Yugabyte Platform allows local network attackers with a compromised user session to change critical security information without re-authentication. An attacker with user session and access to application can modify settings such as password and email without being prompted for the current password, enabling account takeover.
CVE-2025-8286 1 Guralp 1 Fmus 2026-04-15 N/A
The affected products expose an unauthenticated Telnet-based command line interface that could allow an attacker to modify hardware configurations, manipulate data, or factory reset the device.
CVE-2025-3699 2026-04-15 9.8 Critical
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information.
CVE-2025-13510 1 Iskra 2 Ihub, Ihub Lite 2026-04-15 N/A
The Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings.
CVE-2025-11566 1 Schneider-electric 1 Powerchute Serial Shutdown 2026-04-15 N/A
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint.
CVE-2024-10774 1 Sick 2 Inspector61x Firmware, Inspector62x Firmware 2026-04-15 7.3 High
Unauthenticated CROWN APIs allow access to critical functions. This leads to the accessibility of large parts of the web application without authentication.
CVE-2025-30037 1 Cgm 1 Clininet 2026-04-15 N/A
The system exposes several endpoints, typically including "/int/" in their path, that should be restricted to internal services, but are instead publicly accessible without authentication to any host able to reach the application server on port 443/tcp.
CVE-2025-30048 1 Cgm 1 Clininet 2026-04-15 N/A
The "serverConfig" endpoint, which returns the module configuration including credentials, is accessible without authentication.
CVE-2024-31206 2026-04-15 8.2 High
dectalk-tts is a Node package to interact with the aeiou Dectalk web API. In `[email protected]`, network requests to the third-party API are sent over HTTP, which is unencrypted. Unencrypted traffic can be easily intercepted and modified by attackers. Anyone who uses the package could be the victim of a man-in-the-middle (MITM) attack. The network request was upgraded to HTTPS in version `1.0.1`. There are no workarounds, but some precautions include not sending any sensitive information and carefully verifying the API response before saving it.
CVE-2022-43110 1 Voltronicpower 1 Viewpower 2026-04-15 9.8 Critical
Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.
CVE-2025-3759 2026-04-15 N/A
Endpoint /cgi-bin-igd/netcore_set.cgi which is used for changing device configuration is accessible without authentication. This poses a significant security threat allowing for e.g: administrator account hijacking or AP password changing. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-31218 2026-04-15 9.8 Critical
Webhood is a self-hosted URL scanner used analyzing phishing and malicious sites. Webhood's backend container images in versions 0.9.0 and earlier are subject to Missing Authentication for Critical Function vulnerability. This vulnerability allows an unauthenticated attacker to send a HTTP request to the database (Pocketbase) admin API to create an admin account. The Pocketbase admin API does not check for authentication/authorization when creating an admin account when no admin accounts have been added. In its default deployment, Webhood does not create a database admin account. Therefore, unless users have manually created an admin account in the database, an admin account will not exist in the deployment and the deployment is vulnerable. Versions starting from 0.9.1 are patched. The patch creates a randomly generated admin account if admin accounts have not already been created i.e. the vulnerability is exploitable in the deployment. As a workaround, users can disable access to URL path starting with `/api/admins` entirely. With this workaround, the vulnerability is not exploitable via network.
CVE-2024-41276 1 Kaiten 1 Kaiten 2026-04-15 9.8 Critical
A vulnerability in Kaiten version 57.131.12 and earlier allows attackers to bypass the PIN code authentication mechanism. The application requires users to input a 6-digit PIN code sent to their email for authorization after entering their login credentials. However, the request limiting mechanism can be easily bypassed, enabling attackers to perform a brute force attack to guess the correct PIN and gain unauthorized access to the application.
CVE-2025-52392 2026-04-15 5.4 Medium
Soosyze CMS 2.0 allows brute-force login attacks via the /user/login endpoint due to missing rate-limiting and lockout mechanisms. An attacker can repeatedly submit login attempts without restrictions, potentially gaining unauthorized administrative access. This vulnerability corresponds to CWE-307: Improper Restriction of Excessive Authentication Attempts.
CVE-2025-68609 1 Palantir 1 Aries 2026-04-15 6.6 Medium
A vulnerability in Palantir's Aries service allowed unauthenticated access to log viewing and management functionality on Apollo instances using default configuration. The defect resulted in both authentication and authorization checks being bypassed, potentially allowing any network-accessible client to view system logs and perform operations without valid credentials. No evidence of exploitation was identified during the vulnerability window.
CVE-2025-24924 2026-04-15 9.8 Critical
Certain functionality within GMOD Apollo does not require authentication when passed with an administrative username
CVE-2024-45438 2026-04-15 9.1 Critical
An issue was discovered in TitanHQ SpamTitan Email Security Gateway 8.00.x before 8.00.101 and 8.01.x before 8.01.14. The file quarantine.php within the SpamTitan interface allows unauthenticated users to trigger account-level actions using a crafted GET request. Notably, when a non-existent email address is provided as part of the email parameter, SpamTitan will automatically create a user record and associate quarantine settings with it - all without requiring authentication.
CVE-2024-3741 2026-04-15 7.5 High
Electrolink transmitters are vulnerable to an authentication bypass vulnerability affecting the login cookie. An attacker can set an arbitrary value except 'NO' to the login cookie and have full system access.
CVE-2025-0355 2026-04-15 7.5 High
Missing Authentication for Critical Function vulnerability in NEC Corporation Aterm WG2600HS Ver.1.7.2 and earlier, WF1200CRS Ver.1.6.0 and earlier, WG1200CRS Ver.1.5.0 and earlier, GB1200PE Ver.1.3.0 and earlier, WG2600HP4 Ver.1.4.2 and earlier, WG2600HM4 Ver.1.4.2 and earlier, WG2600HS2 Ver.1.3.2 and earlier, WX3000HP Ver.2.4.2 and earlier and WX4200D5 Ver.1.2.4 and earlier allows a attacker to get a Wi-Fi password via the network.
CVE-2025-36535 1 Automationdirect 1 Mb Gateway 2026-04-15 10 Critical
The embedded web server lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality.