Filtered by vendor Schneider-electric Subscriptions
Total 765 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2011-4033 1 Schneider-electric 3 Citecthistorian, Citectscada Reports, Vijeo Historian 2025-04-11 N/A
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors.
CVE-2013-3075 2 Mitsubishi-automation, Schneider-electric 3 Mitsubishi Mx Component, Citectfacilities, Citectscada 2025-04-11 N/A
Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.
CVE-2013-0663 1 Schneider-electric 3 Modicon M340, Modicon Premium, Modicon Quantum Plc 2025-04-11 N/A
Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials.
CVE-2013-2763 1 Schneider-electric 24 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 21 more 2025-04-11 N/A
The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be duplicated" and "an attacker could not remotely exploit this observed behavior to deny PLC control functions.
CVE-2013-0658 1 Schneider-electric 1 Accutech Manager 2025-04-11 N/A
Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request.
CVE-2011-4860 1 Schneider-electric 3 Quantum Ethernet Module 140noe77100, Quantum Ethernet Module 140noe77101, Quantum Ethernet Module 140noe77111 2025-04-11 N/A
The ComputePassword function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device (aka the Quantum 140NOE771* module) generates the password for the fwupgrade account by performing a calculation on the MAC address, which makes it easier for remote attackers to obtain access via a (1) ARP request message or (2) Neighbor Solicitation message.
CVE-2013-2796 1 Schneider-electric 3 Citectscada, Powerlogic Scada, Vijeo Citect 2025-04-11 N/A
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.
CVE-2013-0657 1 Schneider-electric 1 Interactive Graphical Scada System 2025-04-11 N/A
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.
CVE-2011-3330 1 Schneider-electric 6 Monitor Pro, Opc Factory Server, Pl7 Pro and 3 more 2025-04-11 N/A
Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter.
CVE-2013-0655 1 Schneider-electric 1 Software Update Utility 2025-04-11 N/A
The client in Schneider Electric Software Update (SESU) Utility 1.0.x and 1.1.x does not ensure that updates have a valid origin, which allows man-in-the-middle attackers to spoof updates, and consequently execute arbitrary code, by modifying the data stream on TCP port 80.
CVE-2011-4859 1 Schneider-electric 21 M340 Ethernet Module Bmxnoe0100, M340 Ethernet Module Bmxnoe0110, M340 Ethernet Module Bmxp342020 and 18 more 2025-04-11 N/A
The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771* and 140CPU65* modules, the Premium TSXETY* and TSXP57* modules, the M340 BMXNOE01* and BMXP3420* modules, and the STB DIO STBNIC2212 and STBNIP2* modules, uses hardcoded passwords for the (1) AUTCSE, (2) AUT_CSE, (3) fdrusers, (4) ftpuser, (5) loader, (6) nic2212, (7) nimrohs2212, (8) nip2212, (9) noe77111_v500, (10) ntpupdate, (11) pcfactory, (12) sysdiag, (13) target, (14) test, (15) USER, and (16) webserver accounts, which makes it easier for remote attackers to obtain access via the (a) TELNET, (b) Windriver Debug, or (c) FTP port.
CVE-2023-3001 1 Schneider-electric 1 Igss Dashboard 2025-03-05 7.8 High
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file.
CVE-2022-34755 1 Schneider-electric 1 Easergy Builder Installer 2025-03-03 6.3 Medium
A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker with a local privileged account to place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code during the installation process initiated by a valid user. Affected Products: Easergy Builder Installer (1.7.23 and prior)
CVE-2023-25548 1 Schneider-electric 1 Struxureware Data Center Expert 2025-03-03 8.8 High
A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25552 1 Schneider-electric 1 Struxureware Data Center Expert 2025-03-03 8.1 High
A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized content, changes or deleting of content, or performing unauthorized functions when tampering the Device File Transfer settings on DCE endpoints. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25549 1 Schneider-electric 1 Struxureware Data Center Expert 2025-03-03 7.2 High
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-4516 1 Schneider-electric 1 Interactive Graphical Scada System 2025-02-27 7.8 High
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update Service that could allow a local attacker to change update source, potentially leading to remote code execution when the attacker force an update containing malicious content.
CVE-2023-5402 1 Schneider-electric 1 C-bus Toolkit 2025-02-27 9.8 Critical
A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote code execution when the transfer command is used over the network.
CVE-2023-5399 1 Schneider-electric 1 Spacelogic C-bus Toolkit 2025-02-27 9.8 Critical
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause tampering of files on the personal computer running C-Bus when using the File Command.
CVE-2023-5391 1 Schneider-electric 3 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports, Ecostruxure Power Scada Operation With Advanced Reports 2025-02-27 9.8 Critical
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application.