| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| StarWind SAN and NAS v0.2 build 1914 allow remote code execution. A flaw was found in REST API in StarWind Stack. REST command, which allows changing the hostname, doesn’t check a new hostname parameter. It goes directly to bash as part of a script. An attacker with non-root user access can inject arbitrary data into the command that will be executed with root privileges. |
| Tenda AC10 US_AC10V1.0RTL_V15.03.06.26_multi_TD01 was discovered to contain a remote code execution (RCE) vulnerability via the lanIp parameter. |
| MERCURY MIPC451-4 1.0.22 Build 220105 Rel.55642n was discovered to contain a remote code execution (RCE) vulnerability which is exploitable via a crafted POST request. |
| VMware vRealize Operations contains an information disclosure vulnerability. A low-privileged malicious actor with network access can create and leak hex dumps, leading to information disclosure. Successful exploitation can lead to a remote code execution. |
| VMware Workspace ONE Access, Identity Manager and vRealize Automation contain a remote code execution vulnerability. A malicious actor with administrator and network access can trigger a remote code execution. |
| VMware Workspace ONE Access and Identity Manager contain a remote code execution vulnerability. A malicious actor with administrator and network access can trigger a remote code execution. |
| VMware Workspace ONE Access, Identity Manager and vRealize Automation contain a remote code execution vulnerability. A malicious actor with administrator and network access can trigger a remote code execution. |
| In PHP versions 7.4.x below 7.4.30, 8.0.x below 8.0.20, and 8.1.x below 8.1.7, when pdo_mysql extension with mysqlnd driver, if the third party is allowed to supply host to connect to and the password for the connection, password of excessive length can trigger a buffer overflow in PHP, which can lead to a remote code execution vulnerability. |
| A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.13), Teamcenter V13.0 (All versions < V13.0.0.9), Teamcenter V13.1 (All versions < V13.1.0.9), Teamcenter V13.2 (All versions < V13.2.0.9), Teamcenter V13.3 (All versions < V13.3.0.3), Teamcenter V14.0 (All versions < V14.0.0.2). Java EE Server Manager HTML Adaptor in Teamcenter consists of default hardcoded credentials. Access to the application allows a user to perform a series of actions that could potentially lead to remote code execution with elevated permissions. |
| NVFLARE, versions prior to 2.1.2, contains a vulnerability in its utils module, where YAML files are loaded via yaml.load() instead of yaml.safe_load(). The deserialization of Untrusted Data, may allow an unprivileged network attacker to cause Remote Code Execution, Denial Of Service, and Impact to both Confidentiality and Integrity. |
| NVFLARE, versions prior to 2.1.2, contains a vulnerability in its PKI implementation module, where The CA credentials are transported via pickle and no safe deserialization. The deserialization of Untrusted Data may allow an unprivileged network attacker to cause Remote Code Execution, Denial Of Service, and Impact to both Confidentiality and Integrity. |
| Tenda AC18 router V15.03.05.19 and V15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac. |
| Pharmacy Management System v1.0 was discovered to contain a remote code execution (RCE) vulnerability via the component /php_action/editProductImage.php. This vulnerability allows attackers to execute arbitrary code via a crafted image file. |
| FUDforum 3.1.2 is vulnerable to Remote Code Execution through Upload File feature of File Administration System in Admin Control Panel. |
| Webmin through 1.991, when the Authentic theme is used, allows remote code execution when a user has been manually created (i.e., not created in Virtualmin or Cloudmin). This occurs because settings-editor_write.cgi does not properly restrict the file parameter. |
| In Afian Filerun 20220202 Changing the "search_tika_path" variable to a custom (and previously uploaded) jar file results in remote code execution in the context of the webserver user. |
| A Remote Code Execution (RCE) vulnerability exists in waimairen 9.1 via wx.php |
| Proietti Tech srl Planet Time Enterprise 4.2.0.1,4.2.0.0,4.1.0.0,4.0.0.0,3.3.1.0,3.3.0.0 is vulnerable to Remote code execution via the Viewstate parameter. |
| Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service. |
| Honeywell Experion PKS Safety Manager 5.02 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0054, there is a Honeywell Experion PKS Safety Manager unauthenticated firmware update issue. The affected components are characterized as: Firmware update functionality. The potential impact is: Firmware manipulation. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 communication FTA serial interface and Enea POLO bootloader for firmware management purposes. An engineering workstation running the Safety Builder software communicates via serial or serial-over-ethernet link with the DCOM-232/485 interface. Firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks. Firmware images are unsigned. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize hardcoded credentials (see FSCT-2022-0052) for the POLO bootloader to control the boot process and push malicious firmware images to the controller allowing for firmware manipulation, remote code execution and denial of service impacts. A mitigating factor is that in order for a firmware update to be initiated, the Safety Manager has to be rebooted which is typically done by means of physical controls on the Safety Manager itself. As such, an attacker would have to either lay dormant until a legitimate reboot occurs or possibly attempt to force a reboot through a secondary vulnerability. |