| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Sanitization Management System v1.0 was discovered to contain hardcoded credentials which allows attackers to escalate privileges and access the admin panel. |
| Book Store Management System v1.0 was discovered to contain hardcoded credentials which allows attackers to escalate privileges and access the admin panel. |
| A specific file on the sERP server if Kyungrinara(ERP solution) has a fixed password with the SYSTEM authority. This vulnerability could allow attackers to leak or steal sensitive information or execute malicious commands. |
| When aborting a SFTP connection, MobaXterm before v22.1 sends a hardcoded password to the server. The server treats this as an invalid login attempt which can result in a Denial of Service (DoS) for the user if services like fail2ban are used. |
| PuddingBot is a group management bot. In version 0.0.6-b933652 and prior, the bot token is publicly exposed in main.py, making it accessible to malicious actors. The bot token has been revoked and new version is already running on the server. As of time of publication, the maintainers are planning to update code to reflect this change at a later date. |
| Rundeck is an open source automation service with a web console, command line tools and a WebAPI. Rundeck community and rundeck-enterprise docker images contained a pre-generated SSH keypair. If the id_rsa.pub public key of the keypair was copied to authorized_keys files on remote host, those hosts would allow access to anyone with the exposed private credentials. This misconfiguration only impacts Rundeck Docker instances of PagerDuty® Process Automation On Prem (formerly Rundeck) version 4.0 and earlier, not Debian, RPM or .WAR. Additionally, the id_rsa.pub file would have to be copied from the Docker image filesystem contents without overwriting it and used to configure SSH access on a host. A patch on Rundeck's `main` branch has removed the pre-generated SSH key pair, but it does not remove exposed keys that have been configured. To patch, users must run a script on hosts in their environment to search for exposed keys and rotate them. Two workarounds are available: Do not use any pre-existing public key file from the rundeck docker images to allow SSH access by adding it to authorized_keys files and, if you have copied the public key file included in the docker image, remove it from any authorized_keys files. |
| In Pexip VMR self-service portal before 3, the same SSH host key is used across different customers' installations, which allows authentication bypass. |
| Use of hard-coded credentials vulnerability in multiple Buffalo network devices allows a network-adjacent attacker to alter?configuration settings of the device. The affected products/versions are as follows: WZR-300HP firmware Ver. 2.00 and earlier, WZR-450HP firmware Ver. 2.00 and earlier, WZR-600DHP firmware Ver. 2.00 and earlier, WZR-900DHP firmware Ver. 1.15 and earlier, HW-450HP-ZWE firmware Ver. 2.00 and earlier, WZR-450HP-CWT firmware Ver. 2.00 and earlier, WZR-450HP-UB firmware Ver. 2.00 and earlier, WZR-600DHP2 firmware Ver. 1.15 and earlier, and WZR-D1100H firmware Ver. 2.00 and earlier. |
| FlyteAdmin is the control plane for the data processing platform Flyte. Users who enable the default Flyte’s authorization server without changing the default clientid hashes will be exposed to the public internet. In an effort to make enabling authentication easier for Flyte administrators, the default configuration for Flyte Admin allows access for Flyte Propeller even after turning on authentication via a hardcoded hashed password. This password is also set on the default Flyte Propeller configmap in the various Flyte Helm charts. Users who enable auth but do not override this setting in Flyte Admin’s configuration may unbeknownst to them be allowing public traffic in by way of this default password with attackers effectively impersonating propeller. This only applies to users who have not specified the ExternalAuthorizationServer setting. Usage of an external auth server automatically turns off this default configuration and are not susceptible to this vulnerability. This issue has been addressed in version 1.1.44. Users should manually set the staticClients in the selfAuthServer section of their configuration if they intend to rely on Admin’s internal auth server. Again, users who use an external auth server are automatically protected from this vulnerability. |
| Adobe ColdFusion versions Update 14 (and earlier) and Update 4 (and earlier) are affected by a Use of Hard-coded Credentials vulnerability that could result in application denial-of-service by gaining access to start/stop arbitrary services. Exploitation of this issue does not require user interaction. |
| MegaRAC Default Credentials Vulnerability |
| RTL8111EP-CG/RTL8111FP-CG DASH function has hard-coded password. An unauthenticated physical attacker can use the hard-coded default password during system reboot triggered by other user, to acquire partial system information such as serial number and server information. |
| MegaRAC Default Credentials Vulnerability |
| Databasir is a team-oriented relational database model document management platform. Databasir 1.01 has Use of Hard-coded Cryptographic Key vulnerability. An attacker can use hard coding to generate login credentials of any user and log in to the service background located at different IP addresses. |
| iBaby M3S has a password of admin for the backdoor admin account. |
| Lens Peek-a-View has a password of 2601hx for the backdoor admin account, a password of user for the backdoor user account, and a password of guest for the backdoor guest account. |
| Gynoii has a password of guest for the backdoor guest account and a password of 12345 for the backdoor admin account. |
| A Use of Hard-Coded Cryptographic Key issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded private cryptographic keys that may allow an attacker to decrypt traffic from any other source. |
| A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials. |
| A design flaw in the Trane ComfortLink II SCC firmware version 2.0.2 service allows remote attackers to take complete control of the system. |