Filtered by vendor Tenda
Subscriptions
Total
1198 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-2898 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2900 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2901 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2902 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2891 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2560 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-22 | 4.3 Medium |
A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2581 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability. | ||||
CVE-2024-2903 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4064 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-21 | 8.8 High |
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4065 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-21 | 8.8 High |
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4066 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-21 | 8.8 High |
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-3905 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-01-21 | 8.8 High |
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-3906 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-01-21 | 8.8 High |
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-3910 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-01-21 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-3875 | 1 Tenda | 2 F1202, F1202 Firmware | 2025-01-21 | 8.8 High |
A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-3876 | 1 Tenda | 2 F1202, F1202 Firmware | 2025-01-21 | 8.8 High |
A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-3877 | 1 Tenda | 2 F1202, F1202 Firmware | 2025-01-21 | 8.8 High |
A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-3878 | 1 Tenda | 2 F1202, F1202 Firmware | 2025-01-21 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4166 | 1 Tenda | 2 4g300, 4g300 Firmware | 2025-01-21 | 8.8 High |
A vulnerability has been found in Tenda 4G300 1.01.42 and classified as critical. Affected by this vulnerability is the function sub_41E858. The manipulation of the argument GO/page leads to stack-based buffer overflow. The attack can be launched remotely. The identifier VDB-261985 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4167 | 1 Tenda | 2 4g300, 4g300 Firmware | 2025-01-21 | 8.8 High |
A vulnerability was found in Tenda 4G300 1.01.42 and classified as critical. Affected by this issue is the function sub_422AA4. The manipulation of the argument year/month/day/hour/minute/second leads to stack-based buffer overflow. The attack may be launched remotely. VDB-261986 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |