Filtered by vendor Siemens
Subscriptions
Total
1930 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-24556 | 1 Siemens | 1 Solid Edge Se2023 | 2024-11-21 | 7.8 High |
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | ||||
CVE-2023-24555 | 1 Siemens | 2 Solid Edge Se2022, Solid Edge Se2023 | 2024-11-21 | 7.8 High |
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | ||||
CVE-2023-24554 | 1 Siemens | 1 Solid Edge Se2023 | 2024-11-21 | 7.8 High |
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | ||||
CVE-2023-24553 | 1 Siemens | 1 Solid Edge Se2023 | 2024-11-21 | 7.8 High |
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | ||||
CVE-2023-24552 | 1 Siemens | 2 Solid Edge Se2022, Solid Edge Se2023 | 2024-11-21 | 7.8 High |
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process. | ||||
CVE-2023-24551 | 1 Siemens | 1 Solid Edge Se2023 | 2024-11-21 | 7.8 High |
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to heap-based buffer underflow while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. | ||||
CVE-2023-24550 | 1 Siemens | 1 Solid Edge Se2023 | 2024-11-21 | 7.8 High |
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. | ||||
CVE-2023-24549 | 1 Siemens | 1 Solid Edge Se2023 | 2024-11-21 | 7.8 High |
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. | ||||
CVE-2023-24482 | 1 Siemens | 1 Comos | 2024-11-21 | 10 Critical |
A vulnerability has been identified in COMOS V10.2 (All versions), COMOS V10.3.3.1 (All versions < V10.3.3.1.45), COMOS V10.3.3.2 (All versions < V10.3.3.2.33), COMOS V10.3.3.3 (All versions < V10.3.3.3.9), COMOS V10.3.3.4 (All versions < V10.3.3.4.6), COMOS V10.4.0.0 (All versions < V10.4.0.0.31), COMOS V10.4.1.0 (All versions < V10.4.1.0.32), COMOS V10.4.2.0 (All versions < V10.4.2.0.25). Cache validation service in COMOS is vulnerable to Structured Exception Handler (SEH) based buffer overflow. This could allow an attacker to execute arbitrary code on the target system or cause denial of service condition. | ||||
CVE-2023-23588 | 2 Microchip, Siemens | 10 Maxview Storage Manager, Simatic Ipc1047, Simatic Ipc1047 Firmware and 7 more | 2024-11-21 | 6.2 Medium |
A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application. A local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit. | ||||
CVE-2022-47977 | 1 Siemens | 2 Jt Open Toolkit, Jt Utilities | 2024-11-21 | 7.8 High |
A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0). The affected application contains a memory corruption vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. | ||||
CVE-2022-47967 | 1 Siemens | 1 Solid Edge | 2024-11-21 | 7.8 High |
A vulnerability has been identified in Solid Edge (All versions < V2023 MP1). The DOCMGMT.DLL contains a memory corruption vulnerability that could be triggered while parsing files in different file formats such as PAR, ASM, DFT. This could allow an attacker to execute code in the context of the current process. | ||||
CVE-2022-47936 | 1 Siemens | 3 Jt Open Toolkit, Jt Utilities, Parasolid | 2024-11-21 | 7.8 High |
A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. | ||||
CVE-2022-47935 | 1 Siemens | 3 Jt Open Toolkit, Jt Utilities, Solid Edge | 2024-11-21 | 7.8 High |
A vulnerability has been identified in JT Open (All versions < V11.1.1.0), JT Utilities (All versions < V13.1.1.0), Solid Edge (All versions < V2023). The Jt1001.dll contains a memory corruption vulnerability while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19078) | ||||
CVE-2022-47375 | 1 Siemens | 18 6ag1414-3em07-7ab0, 6ag1414-3em07-7ab0 Firmware, 6ag1416-3es07-7ab0 and 15 more | 2024-11-21 | 7.5 High |
A vulnerability has been identified in SIMATICÂ PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly. This could allow an attacker to create a buffer overflow and create a denial of service condition for the device. | ||||
CVE-2022-47374 | 1 Siemens | 18 6ag1414-3em07-7ab0, 6ag1414-3em07-7ab0 Firmware, 6ag1416-3es07-7ab0 and 15 more | 2024-11-21 | 7.5 High |
A vulnerability has been identified in SIMATICÂ PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly. This could allow an attacker to exhaust system resources and create a denial of service condition for the device. | ||||
CVE-2022-46664 | 1 Siemens | 1 Mendix Workflow Commons | 2024-11-21 | 8.1 High |
A vulnerability has been identified in Mendix Workflow Commons (All versions < V2.4.0), Mendix Workflow Commons V2.1 (All versions < V2.1.4), Mendix Workflow Commons V2.3 (All versions < V2.3.2). Affected versions of the module improperly handle access control for some module entities. This could allow authenticated remote attackers to read or delete sensitive information. | ||||
CVE-2022-46355 | 1 Siemens | 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more | 2024-11-21 | 7.5 High |
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The affected products are vulnerable to an "Exposure of Sensitive Information to an Unauthorized Actor" vulnerability by leaking sensitive data in the HTTP Referer. | ||||
CVE-2022-46354 | 1 Siemens | 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more | 2024-11-21 | 5.3 Medium |
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances. | ||||
CVE-2022-46353 | 1 Siemens | 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more | 2024-11-21 | 9.8 Critical |
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions. |