Total
50 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-43474 | 1 Microsoft | 2 Sql Server 2017, Sql Server 2019 | 2025-01-07 | 7.6 High |
Microsoft SQL Server Information Disclosure Vulnerability | ||||
CVE-2023-36907 | 1 Microsoft | 12 Windows 10, Windows 10 1607, Windows 10 1809 and 9 more | 2025-01-01 | 5.5 Medium |
Windows Cryptographic Services Information Disclosure Vulnerability | ||||
CVE-2023-36906 | 1 Microsoft | 12 Windows 10, Windows 10 1607, Windows 10 1809 and 9 more | 2025-01-01 | 5.5 Medium |
Windows Cryptographic Services Information Disclosure Vulnerability | ||||
CVE-2023-35321 | 1 Microsoft | 5 Windows Server 2008, Windows Server 2012, Windows Server 2016 and 2 more | 2025-01-01 | 6.5 Medium |
Windows Deployment Services Denial of Service Vulnerability | ||||
CVE-2024-53110 | 1 Linux | 1 Linux Kernel | 2024-12-19 | 5.5 Medium |
In the Linux kernel, the following vulnerability has been resolved: vp_vdpa: fix id_table array not null terminated error Allocate one extra virtio_device_id as null terminator, otherwise vdpa_mgmtdev_get_classes() may iterate multiple times and visit undefined memory. | ||||
CVE-2024-36897 | 1 Linux | 1 Linux Kernel | 2024-12-19 | 5.5 Medium |
In the Linux kernel, the following vulnerability has been resolved: drm/amd/display: Atom Integrated System Info v2_2 for DCN35 New request from KMD/VBIOS in order to support new UMA carveout model. This fixes a null dereference from accessing Ctx->dc_bios->integrated_info while it was NULL. DAL parses through the BIOS and extracts the necessary integrated_info but was missing a case for the new BIOS version 2.3. | ||||
CVE-2023-52436 | 1 Linux | 1 Linux Kernel | 2024-12-19 | 7.8 High |
In the Linux kernel, the following vulnerability has been resolved: f2fs: explicitly null-terminate the xattr list When setting an xattr, explicitly null-terminate the xattr list. This eliminates the fragile assumption that the unused xattr space is always zeroed. | ||||
CVE-2021-47619 | 1 Linux | 1 Linux Kernel | 2024-12-19 | 5.5 Medium |
In the Linux kernel, the following vulnerability has been resolved: i40e: Fix queues reservation for XDP When XDP was configured on a system with large number of CPUs and X722 NIC there was a call trace with NULL pointer dereference. i40e 0000:87:00.0: failed to get tracking for 256 queues for VSI 0 err -12 i40e 0000:87:00.0: setup of MAIN VSI failed BUG: kernel NULL pointer dereference, address: 0000000000000000 RIP: 0010:i40e_xdp+0xea/0x1b0 [i40e] Call Trace: ? i40e_reconfig_rss_queues+0x130/0x130 [i40e] dev_xdp_install+0x61/0xe0 dev_xdp_attach+0x18a/0x4c0 dev_change_xdp_fd+0x1e6/0x220 do_setlink+0x616/0x1030 ? ahci_port_stop+0x80/0x80 ? ata_qc_issue+0x107/0x1e0 ? lock_timer_base+0x61/0x80 ? __mod_timer+0x202/0x380 rtnl_setlink+0xe5/0x170 ? bpf_lsm_binder_transaction+0x10/0x10 ? security_capable+0x36/0x50 rtnetlink_rcv_msg+0x121/0x350 ? rtnl_calcit.isra.0+0x100/0x100 netlink_rcv_skb+0x50/0xf0 netlink_unicast+0x1d3/0x2a0 netlink_sendmsg+0x22a/0x440 sock_sendmsg+0x5e/0x60 __sys_sendto+0xf0/0x160 ? __sys_getsockname+0x7e/0xc0 ? _copy_from_user+0x3c/0x80 ? __sys_setsockopt+0xc8/0x1a0 __x64_sys_sendto+0x20/0x30 do_syscall_64+0x33/0x40 entry_SYSCALL_64_after_hwframe+0x44/0xae RIP: 0033:0x7f83fa7a39e0 This was caused by PF queue pile fragmentation due to flow director VSI queue being placed right after main VSI. Because of this main VSI was not able to resize its queue allocation for XDP resulting in no queues allocated for main VSI when XDP was turned on. Fix this by always allocating last queue in PF queue pile for a flow director VSI. | ||||
CVE-2024-45288 | 1 Freebsd | 1 Freebsd | 2024-11-21 | 8.4 High |
A missing null-termination character in the last element of an nvlist array string can lead to writing outside the allocated buffer. | ||||
CVE-2021-31888 | 1 Siemens | 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more | 2024-11-21 | 8.8 High |
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018) | ||||
CVE-2021-31887 | 1 Siemens | 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more | 2024-11-21 | 8.8 High |
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016) | ||||
CVE-2021-31886 | 1 Siemens | 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more | 2024-11-21 | 9.8 Critical |
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010) | ||||
CVE-2021-31884 | 1 Siemens | 42 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 39 more | 2024-11-21 | 9.8 Critical |
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The DHCP client application assumes that the data supplied with the “Hostname” DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014) | ||||
CVE-2021-22931 | 5 Netapp, Nodejs, Oracle and 2 more | 13 Active Iq Unified Manager, Nextgen Api, Oncommand Insight and 10 more | 2024-11-21 | 9.8 Critical |
Node.js before 16.6.0, 14.17.4, and 12.22.4 is vulnerable to Remote Code Execution, XSS, Application crashes due to missing input validation of host names returned by Domain Name Servers in Node.js dns library which can lead to output of wrong hostnames (leading to Domain Hijacking) and injection vulnerabilities in applications using the library. | ||||
CVE-2021-1471 | 1 Cisco | 1 Jabber | 2024-11-21 | 9.9 Critical |
Multiple vulnerabilities in Cisco Jabber for Windows, Cisco Jabber for MacOS, and Cisco Jabber for mobile platforms could allow an attacker to execute arbitrary programs on the underlying operating system with elevated privileges, access sensitive information, intercept protected network traffic, or cause a denial of service (DoS) condition. For more information about these vulnerabilities, see the Details section of this advisory. | ||||
CVE-2021-1469 | 1 Cisco | 1 Jabber | 2024-11-21 | 9.9 Critical |
Multiple vulnerabilities in Cisco Jabber for Windows, Cisco Jabber for MacOS, and Cisco Jabber for mobile platforms could allow an attacker to execute arbitrary programs on the underlying operating system with elevated privileges, access sensitive information, intercept protected network traffic, or cause a denial of service (DoS) condition. For more information about these vulnerabilities, see the Details section of this advisory. | ||||
CVE-2021-1418 | 1 Cisco | 1 Jabber | 2024-11-21 | 9.9 Critical |
Multiple vulnerabilities in Cisco Jabber for Windows, Cisco Jabber for MacOS, and Cisco Jabber for mobile platforms could allow an attacker to execute arbitrary programs on the underlying operating system with elevated privileges, access sensitive information, intercept protected network traffic, or cause a denial of service (DoS) condition. For more information about these vulnerabilities, see the Details section of this advisory. | ||||
CVE-2021-1417 | 1 Cisco | 1 Jabber | 2024-11-21 | 9.9 Critical |
Multiple vulnerabilities in Cisco Jabber for Windows, Cisco Jabber for MacOS, and Cisco Jabber for mobile platforms could allow an attacker to execute arbitrary programs on the underlying operating system with elevated privileges, access sensitive information, intercept protected network traffic, or cause a denial of service (DoS) condition. For more information about these vulnerabilities, see the Details section of this advisory. | ||||
CVE-2021-1411 | 1 Cisco | 1 Jabber | 2024-11-21 | 9.9 Critical |
Multiple vulnerabilities in Cisco Jabber for Windows, Cisco Jabber for MacOS, and Cisco Jabber for mobile platforms could allow an attacker to execute arbitrary programs on the underlying operating system with elevated privileges, access sensitive information, intercept protected network traffic, or cause a denial of service (DoS) condition. For more information about these vulnerabilities, see the Details section of this advisory. | ||||
CVE-2021-1120 | 1 Nvidia | 1 Virtual Gpu | 2024-11-21 | 7 High |
NVIDIA vGPU software contains a vulnerability in the Virtual GPU Manager (vGPU plugin), where a string provided by the guest OS may not be properly null terminated. The guest OS or attacker has no ability to push content to the plugin through this vulnerability, which may lead to information disclosure, data tampering, unauthorized code execution, and denial of service. |