Filtered by vendor Ui
Subscriptions
Total
83 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-41721 | 1 Ui | 6 Unifi Dream Machine, Unifi Dream Machine Pro, Unifi Dream Machine Special Edition and 3 more | 2024-11-21 | 5.3 Medium |
Instances of UniFi Network Application that (i) are run on a UniFi Gateway Console, and (ii) are versions 7.5.176. and earlier, implement device adoption with improper access control logic, creating a risk of access to device configuration information by a malicious actor with preexisting access to the network. Affected Products: UDM UDM-PRO UDM-SE UDR UDW Mitigation: Update UniFi Network to Version 7.5.187 or later. | ||||
CVE-2023-32000 | 1 Ui | 1 Unifi Network Application | 2024-11-21 | 4.8 Medium |
A Cross-Site Scripting (XSS) vulnerability found in UniFi Network (Version 7.3.83 and earlier) allows a malicious actor with Site Administrator credentials to escalate privileges by persuading an Administrator to visit a malicious web page. | ||||
CVE-2023-31998 | 1 Ui | 4 Aircube, Aircube Firmware, Edgemax Edgerouter and 1 more | 2024-11-21 | 7.5 High |
A heap overflow vulnerability found in EdgeRouters and Aircubes allows a malicious actor to interrupt UPnP service to said devices. | ||||
CVE-2023-2378 | 1 Ui | 4 Er-x, Er-x-sfp, Er-x-sfp Firmware and 1 more | 2024-11-21 | 6.3 Medium |
A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. It has been rated as critical. Affected by this issue is some unknown functionality of the component Web Management Interface. The manipulation of the argument suffix-rate-up leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-227654 is the identifier assigned to this vulnerability. | ||||
CVE-2023-2377 | 1 Ui | 4 Er-x, Er-x-sfp, Er-x-sfp Firmware and 1 more | 2024-11-21 | 6.3 Medium |
A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component Web Management Interface. The manipulation of the argument name leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227653 was assigned to this vulnerability. | ||||
CVE-2023-2376 | 1 Ui | 4 Er-x, Er-x-sfp, Er-x-sfp Firmware and 1 more | 2024-11-21 | 6.3 Medium |
A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. It has been classified as critical. Affected is an unknown function of the component Web Management Interface. The manipulation of the argument dpi leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-227652. | ||||
CVE-2023-2375 | 1 Ui | 4 Er-x, Er-x-sfp, Er-x-sfp Firmware and 1 more | 2024-11-21 | 6.3 Medium |
A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6 and classified as critical. This issue affects some unknown processing of the component Web Management Interface. The manipulation of the argument src leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-227651. | ||||
CVE-2023-2374 | 1 Ui | 4 Er-x, Er-x-sfp, Er-x-sfp Firmware and 1 more | 2024-11-21 | 6.3 Medium |
A vulnerability has been found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6 and classified as critical. This vulnerability affects unknown code of the component Web Management Interface. The manipulation of the argument ecn-down leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-227650 is the identifier assigned to this vulnerability. | ||||
CVE-2023-1458 | 1 Ui | 2 Edgerouter X, Edgerouter X Firmware | 2024-11-21 | 7.2 High |
A vulnerability has been found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6 and classified as critical. Affected by this vulnerability is an unknown functionality of the component OSPF Handler. The manipulation of the argument area leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The associated identifier of this vulnerability is VDB-223303. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities. | ||||
CVE-2023-1457 | 1 Ui | 2 Edgerouter X, Edgerouter X Firmware | 2024-11-21 | 7.2 High |
A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. Affected is an unknown function of the component Static Routing Configuration Handler. The manipulation of the argument next-hop-interface leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. VDB-223302 is the identifier assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities. | ||||
CVE-2023-1456 | 1 Ui | 2 Edgerouter X, Edgerouter X Firmware | 2024-11-21 | 7.2 High |
A vulnerability, which was classified as critical, has been found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. This issue affects some unknown processing of the component NAT Configuration Handler. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The identifier VDB-223301 was assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities. | ||||
CVE-2022-43553 | 1 Ui | 2 Edgemax Edgerouter, Edgemax Edgerouter Firmware | 2024-11-21 | 8.8 High |
A remote code execution vulnerability in EdgeRouters (Version 2.0.9-hotfix.4 and earlier) allows a malicious actor with an operator account to run arbitrary administrator commands.This vulnerability is fixed in Version 2.0.9-hotfix.5 and later. | ||||
CVE-2022-35257 | 1 Ui | 1 Desktop | 2024-11-21 | 7.8 High |
A local privilege escalation vulnerability in UI Desktop for Windows (Version 0.55.1.2 and earlier) allows a malicious actor with local access to a Windows device with UI Desktop to run arbitrary commands as SYSTEM. | ||||
CVE-2022-22570 | 1 Ui | 2 Ua Lite, Ua Lite Firmware | 2024-11-21 | 10.0 Critical |
A buffer overflow vulnerability found in the UniFi Door Access Reader Lite’s (UA Lite) firmware (Version 3.8.28.24 and earlier) allows a malicious actor who has gained access to a network to control all connected UA devices. This vulnerability is fixed in Version 3.8.31.13 and later. | ||||
CVE-2021-44530 | 1 Ui | 1 Unifi Network Controller | 2024-11-21 | 9.8 Critical |
An injection vulnerability exists in a third-party library used in UniFi Network Version 6.5.53 and earlier (Log4J CVE-2021-44228) allows a malicious actor to control the application. | ||||
CVE-2021-44527 | 1 Ui | 1 Unifi Switch Firmware | 2024-11-21 | 6.5 Medium |
A vulnerability found in UniFi Switch firmware Version 5.43.35 and earlier allows a malicious actor who has already gained access to the network to perform a Deny of Service (DoS) attack on the affected switch.This vulnerability is fixed in UniFi Switch firmware 5.76.6 and later. | ||||
CVE-2021-33820 | 1 Ui | 2 Camera G3 Flex, Camera G3 Flex Firmware | 2024-11-21 | 7.5 High |
An issue was discovered in UniFi Protect G3 FLEX Camera Version UVC.v4.30.0.67.Attacker could send a huge amount of TCP SYN packet to make web service's resource exhausted. Then the web server is denial-of-service. | ||||
CVE-2021-33818 | 1 Ui | 2 Camera G3 Flex, Camera G3 Flex Firmware | 2024-11-21 | 7.5 High |
An issue was discovered in UniFi Protect G3 FLEX Camera Version UVC.v4.30.0.67. Attackers can use slowhttptest tool to send incomplete HTTP request, which could make server keep waiting for the packet to finish the connection, until its resource exhausted. Then the web server is denial-of-service. | ||||
CVE-2021-22957 | 1 Ui | 1 Unifi Protect | 2024-11-21 | 8.8 High |
A Cross-Origin Resource Sharing (CORS) vulnerability found in UniFi Protect application Version 1.19.2 and earlier allows a malicious actor who has convinced a privileged user to access a URL with malicious code to take over said user’s account.This vulnerability is fixed in UniFi Protect application Version 1.20.0 and later. | ||||
CVE-2021-22952 | 1 Ui | 1 Unifi Talk | 2024-11-21 | 8.8 High |
A vulnerability found in UniFi Talk application V1.12.3 and earlier permits a malicious actor who has already gained access to a network to subsequently control Talk device(s) assigned to said network if they are not yet adopted. This vulnerability is fixed in UniFi Talk application V1.12.5 and later. |