Filtered by vendor Tenda
Subscriptions
Total
1198 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-4494 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4495 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4496 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4237 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-01-27 | 8.8 High |
A vulnerability, which was classified as critical, was found in Tenda AX1806 1.0.0.1. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4238 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-01-27 | 8.8 High |
A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4239 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-01-27 | 8.8 High |
A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4240 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4241 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4242 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4243 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4244 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4245 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4246 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). This affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4497 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4247 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4252 | 1 Tenda | 2 I22, I22 Firmware | 2025-01-27 | 8.8 High |
A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4248 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4249 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4250 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-4251 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |