Total
29474 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2019-11782 | 1 Odoo | 1 Odoo | 2024-11-21 | 6.5 Medium |
Improper access control in Odoo Community 14.0 and earlier and Odoo Enterprise 14.0 and earlier, allows remote authenticated users with access to contact management to modify user accounts, leading to privilege escalation. | ||||
CVE-2019-11780 | 1 Odoo | 1 Odoo | 2024-11-21 | 8.1 High |
Improper access control in the computed fields system of the framework of Odoo Community 13.0 and Odoo Enterprise 13.0 allows remote authenticated attackers to access sensitive information via crafted RPC requests, which could lead to privilege escalation. | ||||
CVE-2019-11288 | 1 Pivotal | 2 Tc Runtimes, Tc Server | 2024-11-21 | 7.0 High |
In Pivotal tc Server, 3.x versions prior to 3.2.19 and 4.x versions prior to 4.0.10, and Pivotal tc Runtimes, 7.x versions prior to 7.0.99.B, 8.x versions prior to 8.5.47.A, and 9.x versions prior to 9.0.27.A, when a tc Runtime instance is configured with the JMX Socket Listener, a local attacker without access to the tc Runtime process or configuration files is able to manipulate the RMI registry to perform a man-in-the-middle attack to capture user names and passwords used to access the JMX interface. The attacker can then use these credentials to access the JMX interface and gain complete control over the tc Runtime instance. | ||||
CVE-2019-11279 | 1 Cloudfoundry | 1 Uaa Release | 2024-11-21 | 8.8 High |
CF UAA versions prior to 74.1.0 can request scopes for a client that shouldn't be allowed by submitting an array of requested scopes. A remote malicious user can escalate their own privileges to any scope, allowing them to take control of UAA and the resources it controls. | ||||
CVE-2019-11278 | 1 Cloudfoundry | 1 User Account And Authentication | 2024-11-21 | 8.8 High |
CF UAA versions prior to 74.1.0, allow external input to be directly queried against. A remote malicious user with 'client.write' and 'groups.update' can craft a SCIM query, which leaks information that allows an escalation of privileges, ultimately allowing the malicious user to gain control of UAA scopes they should not have. | ||||
CVE-2019-11254 | 2 Kubernetes, Redhat | 2 Kubernetes, Openshift | 2024-11-21 | 6.5 Medium |
The Kubernetes API Server component in versions 1.1-1.14, and versions prior to 1.15.10, 1.16.7 and 1.17.3 allows an authorized user who sends malicious YAML payloads to cause the kube-apiserver to consume excessive CPU cycles while parsing YAML. | ||||
CVE-2019-11147 | 1 Intel | 4 Converged Security Management Engine Firmware, Intel-sa-00125 Detection Tool, Sa-00086 Detection Tool and 1 more | 2024-11-21 | 7.8 High |
Insufficient access control in hardware abstraction driver for MEInfo software for Intel(R) CSME before versions 11.8.70, 11.11.70, 11.22.70, 12.0.45, 13.0.0, 14.0.10; TXEInfo software for Intel(R) TXE before versions 3.1.70 and 4.0.20; INTEL-SA-00086 Detection Tool version 1.2.7.0 or before; INTEL-SA-00125 Detection Tool version 1.0.45.0 or before may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||
CVE-2019-11044 | 3 Fedoraproject, Php, Tenable | 3 Fedora, Php, Securitycenter | 2024-11-21 | 3.7 Low |
In PHP versions 7.2.x below 7.2.26, 7.3.x below 7.3.13 and 7.4.0 on Windows, PHP link() function accepts filenames with embedded \0 byte and treats them as terminating at that byte. This could lead to security vulnerabilities, e.g. in applications checking paths that the code is allowed to access. | ||||
CVE-2019-10988 | 1 Philips | 2 Hdi 4000, Hdi 4000 Firmware | 2024-11-21 | 3.4 Low |
In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploited to affect this product. | ||||
CVE-2019-10984 | 1 Redlion | 1 Crimson | 2024-11-21 | 7.8 High |
Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that causes the program to mishandle pointers. | ||||
CVE-2019-10970 | 1 Rockwellautomation | 2 Panelview 5510, Panelview 5510 Firmware | 2024-11-21 | 9.8 Critical |
In Rockwell Automation PanelView 5510 (all versions manufactured before March 13, 2019 that have never been updated to v4.003, v5.002, or later), a remote, unauthenticated threat actor with access to an affected PanelView 5510 Graphic Display, upon successful exploit, may boot-up the terminal and gain root-level access to the device’s file system. | ||||
CVE-2019-10968 | 1 Philips | 1 Zymed Holter 2010 | 2024-11-21 | 4.4 Medium |
Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled. | ||||
CVE-2019-10963 | 1 Moxa | 2 Edr-810, Edr-810 Firmware | 2024-11-21 | 4.3 Medium |
Moxa EDR 810, all versions 5.1 and prior, allows an unauthenticated attacker to be able to retrieve some log files from the device, which may allow sensitive information disclosure. Log files must have previously been exported by a legitimate user. | ||||
CVE-2019-10962 | 1 Bd | 2 Alaris Gateway Workstation, Alaris Gateway Workstation Firmware | 2024-11-21 | 5.3 Medium |
BD Alaris Gateway versions, 1.0.13,1.1.3 Build 10,1.1.3 MR Build 11,1.1.5, and 1.1.6, The web browser user interface on the Alaris Gateway Workstation does not prevent an attacker with knowledge of the IP address of the Alaris Gateway Workstation terminal to gain access to the status and configuration information of the device. | ||||
CVE-2019-10939 | 1 Siemens | 10 Tim 3v-ie, Tim 3v-ie Advanced, Tim 3v-ie Advanced Firmware and 7 more | 2024-11-21 | 9.8 Critical |
A vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3). The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known. | ||||
CVE-2019-10938 | 1 Siemens | 25 6md85, 6md86, 6md89 and 22 more | 2024-11-21 | 9.8 Critical |
A vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions < V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions < V8.01), Siemens Power Meters Series 9410 (All versions < V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is executed before firmware verification in the device. At the time of advisory publication no public exploitation of this security vulnerability was known. | ||||
CVE-2019-10931 | 1 Siemens | 28 6md85, 6md86, 6md89 and 25 more | 2024-11-21 | 7.5 High |
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition. | ||||
CVE-2019-10929 | 1 Siemens | 33 Simatic Cp 1626, Simatic Cp 1626 Firmware, Simatic Et 200sp Open Controller Cpu 1515sp Pc and 30 more | 2024-11-21 | 5.9 Medium |
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices. | ||||
CVE-2019-10928 | 1 Siemens | 2 Scalance Sc-600, Scalance Sc-600 Firmware | 2024-11-21 | 6.6 Medium |
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device. | ||||
CVE-2019-10927 | 1 Siemens | 10 Scalance Xb-200, Scalance Xb-200 Firmware, Scalance Xc-200 and 7 more | 2024-11-21 | 6.5 Medium |
A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the availability of the affected device. |