Filtered by vendor Siemens Subscriptions
Total 1930 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-45204 1 Siemens 1 Tecnomatix 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a type confusion vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21268)
CVE-2023-44373 1 Siemens 142 6ag1206-2bb00-7ac2, 6ag1206-2bb00-7ac2 Firmware, 6ag1206-2bs00-7ac2 and 139 more 2024-11-21 9.1 Critical
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V2.4.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V2.4.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V2.4.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V2.4.0), SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) (All versions < V2.4.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V2.4.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V2.4.0), SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) (All versions < V2.4.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V2.4.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V2.4.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V2.4.0), SCALANCE WUB762-1 (6GK5762-1AJ00-2AA0) (All versions < V2.4.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V2.4.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V2.4.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V2.4.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V2.4.0), SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) (All versions < V2.4.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V2.4.0), SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) (All versions < V2.4.0). Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.
CVE-2023-44321 1 Siemens 142 6ag1206-2bb00-7ac2, 6ag1206-2bb00-7ac2 Firmware, 6ag1206-2bs00-7ac2 and 139 more 2024-11-21 2.7 Low
Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again.
CVE-2023-44315 1 Siemens 1 Sinec Nms 2024-11-21 4.7 Medium
A vulnerability has been identified in SINEC NMS (All versions < V2.0). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could prepare a stored cross-site scripting (XSS) attack that may lead to unintentional modification of application data by legitimate users.
CVE-2023-44120 1 Siemens 1 Spectrum Power 7 2024-11-21 7.8 High
A vulnerability has been identified in Spectrum Power 7 (All versions < V23Q4). The affected product's sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.
CVE-2023-44087 1 Siemens 1 Tecnomatix 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-44086 1 Siemens 1 Tecnomatix 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-44085 1 Siemens 1 Tecnomatix 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-44084 1 Siemens 1 Tecnomatix 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-44083 1 Siemens 1 Tecnomatix 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.
CVE-2023-44082 1 Siemens 1 Tecnomatix 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.
CVE-2023-44081 1 Siemens 1 Tecnomatix 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.
CVE-2023-43625 1 Siemens 1 Simcenter Amesim 2024-11-21 9.8 Critical
A vulnerability has been identified in Simcenter Amesim (All versions < V2021.1). The affected application contains a SOAP endpoint that could allow an unauthenticated remote attacker to perform DLL injection and execute arbitrary code in the context of the affected application process.
CVE-2023-42797 1 Siemens 4 Sicam A8000 Cp-8031, Sicam A8000 Cp-8031 Firmware, Sicam A8000 Cp-8050 and 1 more 2024-11-21 6.6 Medium
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.20), CP-8050 MASTER MODULE (All versions < CPCI85 V05.20). The network configuration service of affected devices contains a flaw in the conversion of ipv4 addresses that could lead to an uninitialized variable being used in succeeding validation steps. By uploading specially crafted network configuration, an authenticated remote attacker could be able to inject commands that are executed on the device with root privileges during device startup.
CVE-2023-42796 1 Siemens 4 Cp-8031, Cp-8031 Firmware, Cp-8050 and 1 more 2024-11-21 7.5 High
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11). The web server of affected devices fails to properly sanitize user input for the /sicweb-ajax/tmproot/ endpoint. This could allow an authenticated remote attacker to traverse directories on the system and download arbitrary files. By exploring active session IDs, the vulnerability could potentially be leveraged to escalate privileges to the administrator role.
CVE-2023-41846 1 Siemens 1 Tecnomatix 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to memory corruption while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-41033 1 Siemens 2 Parasolid, Simcenter Femap 2024-11-21 7.8 High
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.260), Parasolid V35.1 (All versions < V35.1.246), Parasolid V36.0 (All versions < V36.0.156), Simcenter Femap V2301 (All versions < V2301.0003), Simcenter Femap V2306 (All versions < V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21266)
CVE-2023-40732 1 Siemens 1 Qms Automotive 2024-11-21 3.9 Low
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.
CVE-2023-40731 1 Siemens 1 Qms Automotive 2024-11-21 5.7 Medium
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The affected application allows users to upload arbitrary file types. This could allow an attacker to upload malicious files, that could potentially lead to code tampering.
CVE-2023-40730 1 Siemens 1 Qms Automotive 2024-11-21 7.1 High
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected application lacks sufficient authorization checks. This could allow an attacker to access confidential information, perform administrative functions, or lead to a denial-of-service condition.