CVE-2025-40763 1 Siemens 1 Altair Grid Engine 2026-04-15 7.8 High
A vulnerability has been identified in Altair Grid Engine (All versions < V2026.0.0). Affected products do not properly validate environment variables when loading shared libraries, allowing path hijacking through malicious library substitution. This could allow a local attacker to execute arbitrary code with superuser privileges by manipulating the environment variable and placing a malicious library in the controlled path.
CVE-2025-40760 1 Siemens 1 Altair Grid Engine 2026-04-15 5.5 Medium
A vulnerability has been identified in Altair Grid Engine (All versions < V2026.0.0). Affected products do not properly handle error messages and discloses sensitive password hash information when processing user authentication requests. This could allow a local attacker to extract password hashes for privileged accounts, which can then be subjected to offline brute-force attacks.
CVE-2023-32737 1 Siemens 1 Simatic Step 7 2026-04-15 6.3 Medium
A vulnerability has been identified in SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
CVE-2023-32736 1 Siemens 9 Simatic S7-plcsim, Simatic Step 7, Simatic Wincc and 6 more 2026-04-15 7.3 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2024-35783 1 Siemens 6 Simatic Batch, Simatic Information Server, Simatic Pcs7 and 3 more 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
CVE-2024-52335 1 Siemens 1 Syngo Plaza Vb30e 2026-04-15 9.8 Critical
A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF05). The affected application do not properly sanitize input data before sending it to the SQL server. This could allow an attacker with access to the application could use this vulnerability to execute malicious SQL commands to compromise the whole database.
CVE-2024-32010 1 Siemens 1 Spectrum Power 4 2026-04-15 7.8 High
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to extraction of database credentials via a world-readable credential file. This allows an attacker to connect to the database as privileged application user and to run system commands via the database.
CVE-2024-32009 1 Siemens 1 Spectrum Power 4 2026-04-15 7.8 High
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to a local privilege escalation due to wrongly set permissions to a binary which allows any local attacker to gain administrative privileges.
CVE-2025-23403 1 Siemens 2 Simatic Ipc Diagbase, Simatic Ipc Diagmonitor 2026-04-15 7 High
A vulnerability has been identified in SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions). The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to privilege escalation or bypassing endpoint protection and other security measures.
CVE-2024-45032 1 Siemens 2 Industrial Edge Management Pro, Industrial Edge Management Virtual 2026-04-15 10 Critical
A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Affected components do not properly validate the device tokens. This could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system.
CVE-2023-49069 1 Siemens 1 Mendix 2026-04-15 5.3 Medium
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.17.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions < V10.12.11 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions < V10.6.19 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions < V8.18.33 only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions < V9.24.31 only if the basic authentication mechanism is used by the application). The authentication mechanism of affected applications contains an observable response discrepancy vulnerability when validating usernames. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames.
CVE-2011-20002 1 Siemens 3 Simatic, Simatic S7-1200, Simatic S7-1200 Cpu 2026-04-15 7.4 High
A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.2), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.2). Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This could allow an on-path attacker between the engineering software and the controller to execute any previously recorded commands at a later time (e.g. set the controller to STOP), regardless whether or not the controller had a password configured.
CVE-2024-37997 1 Siemens 2 Jt Open, Plm Xml Sdk 2026-04-15 7.8 High
A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
CVE-2022-45147 1 Siemens 2 Simatic Pcs Neo, Simatic Step 7 2026-04-15 7.8 High
A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
CVE-2011-20001 1 Siemens 3 Simatic, Simatic S7-1200, Simatic S7-1200 Cpu 2026-04-15 7.5 High
A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.3), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.3). The web server interface of affected devices improperly processes incoming malformed HTTP traffic at high rate. This could allow an unauthenticated remote attacker to force the device entering the stop/defect state, thus creating a denial of service condition.
CVE-2026-27664 1 Siemens 2 Cpci85 Central Processing\/communication, Sicore Base System 2026-04-14 7.5 High
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.10), SICORE Base system (All versions < V26.10.0). The affected application contains an out-of-bounds write vulnerability while parsing specially crafted XML inputs. This could allow an unauthenticated attacker to exploit this issue by sending a malicious XML request, which may cause the service to crash, resulting in a denial-of-service condition.
CVE-2026-27663 1 Siemens 2 Cpci85 Central Processing\/communication, Rtum85 rtu Base 2026-04-14 6.5 Medium
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.10), RTUM85 RTU Base (All versions < V26.10). The affected application contains denial-of-service (DoS) vulnerability. The remote operation mode is susceptible to a resource exhaustion condition when subjected to a high volume of requests. Sending multiple requests can exhaust resources, preventing parameterization and requiring a reset or reboot to restore functionality.
CVE-2020-26147 5 Arista, Debian, Linux and 2 more 15 C-65, C-65 Firmware, C-75 and 12 more 2026-04-14 5.4 Medium
An issue was discovered in the Linux kernel 5.8.9. The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. This vulnerability can be abused to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used.
CVE-2023-44373 1 Siemens 142 6ag1206-2bb00-7ac2, 6ag1206-2bb00-7ac2 Firmware, 6ag1206-2bs00-7ac2 and 139 more 2026-04-14 9.1 Critical
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.
CVE-2022-36325 1 Siemens 180 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 177 more 2026-04-14 6.8 Medium
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.