| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Xerox AltaLink B8045/B8055/B8065/B8075/B8090, AltaLink C8030/C8035/C8045/C8055/C8070 with software releases before 103.xxx.030.32000 includes two accounts with weak hard-coded passwords which can be exploited and allow unauthorized access which cannot be disabled. |
| Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue. |
| Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes. |
| Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password may allow an attacker with physical access to the device to access management functions to make unauthorized configuration changes to biomedical settings such as turn on and off wireless connections and the phase-complete audible alarm that indicates the end of an infusion phase. Baxter has released a new version of the SIGMA Spectrum Infusion System, version 8, which incorporates hardware and software changes. |
| A vulnerability in Cisco Firepower Threat Defense (FTD) Software for Cisco Firepower 1000, 2100, 3100, and 4200 Series could allow an unauthenticated, local attacker to access an affected system using static credentials.
This vulnerability is due to the presence of static accounts with hard-coded passwords on an affected system. An attacker could exploit this vulnerability by logging in to the CLI of an affected device with these credentials. A successful exploit could allow the attacker to access the affected system and retrieve sensitive information, perform limited troubleshooting actions, modify some configuration options, or render the device unable to boot to the operating system, requiring a reimage of the device. |
| The web application for ProGauge MAGLINK LX4 CONSOLE contains an
administrative-level user account with a password that cannot be
changed. |
| Dell SmartFabric OS10 Software, version(s) 10.5.5.4 through 10.5.5.10 and 10.5.6.x, contain(s) an Use of Hard-coded Password vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Client-side request forgery and Information disclosure. |
| A vulnerability classified as critical was found in TOTOLINK AC1200 T8 4.1.5cu.861_B20230220. This vulnerability affects unknown code of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Identical Hardcoded Root Password for All Devices in GNCC's GC2 Indoor Security Camera 1080P allows an attacker with physical access to retrieve the root password for all similar devices |
| A vulnerability was found in TOTOLINK CP450 4.1.0cu.747_B20191224. It has been classified as critical. This affects an unknown part of the file /web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-273255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service. |