Filtered by vendor Tenda
Subscriptions
Filtered by product Ac7
Subscriptions
Total
41 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2018-14558 | 1 Tenda | 6 Ac10, Ac10 Firmware, Ac7 and 3 more | 2025-02-04 | 9.8 Critical |
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input. | ||||
CVE-2024-2892 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2893 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2894 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2895 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2896 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2897 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 6.3 Medium |
A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2899 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2898 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2900 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2901 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2902 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2891 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2903 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2023-41562 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2024-11-21 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. | ||||
CVE-2023-41559 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2024-11-21 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. | ||||
CVE-2023-41558 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg. | ||||
CVE-2023-41557 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac7 and 1 more | 2024-11-21 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat. | ||||
CVE-2023-41556 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2024-11-21 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. | ||||
CVE-2023-41555 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet. |